Inter-subject variability in human atrial action potential in sinus rhythm versus chronic atrial fibrillation
Financiación FP7 / Fp7 Funds
Resumen: Aims: Human atrial electrophysiology exhibits high inter-subject variability in both sinus rhythm (SR) and chronic atrial fibrillation (cAF) patients. Variability is however rarely investigated in experimental and theoretical electrophysiological studies, thus hampering the understanding of its underlying causes but also its implications in explaining differences in the response to disease and treatment. In our study, we aim at investigating the ability of populations of human atrial cell models to capture the inter-subject variability in action potential (AP) recorded in 363 patients both under SR and cAF conditions.
Methods and Results: Human AP recordings in atrial trabeculae (n?=?469) from SR and cAF patients were used to calibrate populations of computational SR and cAF atrial AP models. Three populations of over 2000 sampled models were generated, based on three different human atrial AP models. Experimental calibration selected populations of AP models yielding AP with morphology and duration in range with experimental recordings. Populations using the three original models can mimic variability in experimental AP in both SR and cAF, with median conductance values in SR for most ionic currents deviating less than 30% from their original peak values. All cAF populations show similar variations in GK1, GKur and Gto, consistent with AF-related remodeling as reported in experiments. In all SR and cAF model populations, inter-subject variability in IK1 and INaK underlies variability in APD90, variability in IKur, ICaL and INaK modulates variability in APD50 and combined variability in Ito and IKur determines variability in APD20. The large variability in human atrial AP triangulation is mostly determined by IK1 and either INaK or INaCa depending on the model.
Conclusion: Experimentally-calibrated human atrial AP models populations mimic AP variability in SR and cAF patient recordings, and identify potential ionic determinants of inter-subject variability in human atrial AP duration and morphology in SR versus cAF.

Idioma: Inglés
DOI: 10.1371/journal.pone.0105897
Año: 2014
Publicado en: PLoS ONE 9, 8 (2014), e105897 [14 pp]
ISSN: 1932-6203

Factor impacto JCR: 3.234 (2014)
Categ. JCR: MULTIDISCIPLINARY SCIENCES rank: 9 / 57 = 0.158 (2014) - Q1 - T1
Financiación: info:eu-repo/grantAgreement/EC/FP7/261057/EU/The European Network for Translational Research in Atrial Fibrillation/EUTRAF
Financiación: info:eu-repo/grantAgreement/ES/MINECO/TEC2010-19410
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2019-05-29-11:38:02)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2016-12-14, última modificación el 2019-05-29


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)