Experimental approach for the uncertainty assessment of 3D complex geometry dimensional measurements using computed tomography at the mm and sub-mm scales
Resumen: The dimensional verification of miniaturized components with 3D complex geometries is particularly challenging. Computed Tomography (CT) can represent a suitable alternative solution to micro metrology tools based on optical and tactile techniques. However, the establishment of CT systems’ traceability when measuring 3D complex geometries is still an open issue. In this work, an alternative method for the measurement uncertainty assessment of 3D complex geometries by using CT is presented. The method is based on the micro-CT system Maximum Permissible Error (MPE) estimation, determined experimentally by using several calibrated reference artefacts. The main advantage of the presented method is that a previous calibration of the component by a more accurate Coordinate Measuring System (CMS) is not needed. In fact, such CMS would still hold all the typical limitations of optical and tactile techniques, particularly when measuring miniaturized components with complex 3D geometries and their inability to measure inner parts. To validate the presented method, the most accepted standard currently available for CT sensors, the Verein Deutscher Ingenieure/Verband Deutscher Elektrotechniker (VDI/VDE) guideline 2630-2.1 is applied. Considering the high number of influence factors in CT and their impact on the measuring result, two different techniques for surface extraction are also considered to obtain a realistic determination of the influence of data processing on uncertainty. The uncertainty assessment of a workpiece used for micro mechanical material testing is firstly used to confirm the method, due to its feasible calibration by an optical CMS. Secondly, the measurement of a miniaturized dental file with 3D complex geometry is carried out. The estimated uncertainties are eventually compared with the component’s calibration and the micro manufacturing tolerances to demonstrate the suitability of the presented CT calibration procedure. The 2U/T ratios resulting from the validation workpiece are, respectively, 0.27 (VDI) and 0.35 (MPE), by assuring tolerances in the range of +- 20–30 micro-m. For the dental file, the EN < 1 value analysis is favorable in the majority of the cases (70.4%) and 2U/T is equal to 0.31 for sub-mm measurands (L < 1 mm and tolerance intervals of +- 40–80 micro-m).
Idioma: Inglés
DOI: 10.3390/s17051137
Año: 2017
Publicado en: SENSORS 17 (2017), 1137
ISSN: 1424-8220

Factor impacto JCR: 2.475 (2017)
Categ. JCR: CHEMISTRY, ANALYTICAL rank: 30 / 80 = 0.375 (2017) - Q2 - T2
Categ. JCR: INSTRUMENTS & INSTRUMENTATION rank: 16 / 61 = 0.262 (2017) - Q2 - T1
Categ. JCR: ELECTROCHEMISTRY rank: 15 / 28 = 0.536 (2017) - Q3 - T2

Factor impacto SCIMAGO: 0.584 - Analytical Chemistry (Q2) - Atomic and Molecular Physics, and Optics (Q2) - Medicine (miscellaneous) (Q2) - Electrical and Electronic Engineering (Q2) - Instrumentation (Q2) - Biochemistry (Q3)

Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2015-69403-C3-1-R
Financiación: info:eu-repo/grantAgreement/ES/UZ/CUD2016-TEC-09
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Ing. Procesos Fabricación (Dpto. Ingeniería Diseño Fabri.)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2019-07-09-11:59:20)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2017-07-03, última modificación el 2019-07-09


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)