Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: On the effect of the band size on the myopization

Lanchares, E. (Universidad de Zaragoza) ; Buey, M.A.D. (Universidad de Zaragoza) ; Cristóbal, J.A. (Universidad de Zaragoza) ; Calvo, B. (Universidad de Zaragoza) ; Ascaso, F.J. (Universidad de Zaragoza) ; Malvè, M.
Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: On the effect of the band size on the myopization
Resumen: A finite element model (FE) of the eye including cornea, sclera, crystalline lens, and ciliary body was created to analyze the influence of the silicone encircling bandwidth and the tightness degree on the myopia induced by scleral buckling (SB) procedure for rhegmatogenous retinal detachment. Intraocular pressure (IOP) was applied to the reference geometry of the FE model and then SB surgery was simulated with encircling bandwidths of 1, 2, and 2.5 mm. Different levels of tightening and three values of IOP were applied. The anterior segment resulted as unaffected by the surgery. The highest value of Cauchy stress appeared in the surroundings of the implant, whereas no increment of stress was observed either in anterior segment or in the optic nerve head. The initial IOP did not appear to play any role in the induced myopia. The wider the band, the greater the induced myopia: 0.44, 0.88, and 1.07 diopters (D) for the 1, 2, and 2.5 mm bandwidth, respectively. Therefore, patients become more myopic with a wider encircling element. The proposed simulations allow determining the effect of the bandwidth or the tightness degree on the axial lengthening, thus predicting the myopic increment caused by the encircling surgery.
Idioma: Inglés
DOI: 10.1155/2016/3578617
Año: 2016
Publicado en: Journal of Ophthalmology 2016 (2016), 3578617 [11 pp]
ISSN: 2090-004X

Factor impacto JCR: 1.712 (2016)
Categ. JCR: OPHTHALMOLOGY rank: 35 / 59 = 0.593 (2016) - Q3 - T2
Categ. JCR: MEDICINE, RESEARCH & EXPERIMENTAL rank: 84 / 128 = 0.656 (2016) - Q3 - T2

Factor impacto SCIMAGO: 0.812 - Ophthalmology (Q2)

Financiación: info:eu-repo/grantAgreement/ES/DGA/T88
Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2014-54981-R
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Oftalmología (Dpto. Cirugía,Ginecol.Obstetr.)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2020-02-21-13:52:11)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2018-02-21, última modificación el 2020-02-21


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)