The CUORE cryostat and its bolometric detector

Alduino, C. ; Alfonso, K. ; Artusa, D. R. ; Avignone, F. T. ; Azzolini, O. ; Bari, G. ; Beeman, J. W. ; Bellini, F. ; Benato, G. ; Bersani, A. ; Biassoni, M. ; Branca, A. ; Brofferio, C. ; Bucci, C. ; Camacho, A. ; Caminata, A. ; Canonica, L. ; Cao, X. G. ; Capelli, S. ; Cappelli, L. ; Cardani, L. ; Carniti, P. ; Casali, N. ; Cassina, L. ; Chiesa, D. ; Chott, N. ; Clemenza, M. ; Copello, S. ; Cosmelli, C. ; Cremonesi, O. ; Creswick, R. J. ; Cushman, J. S. ; D'Addabbo, A. ; D'Aguanno, D. ; Dafinei, I. ; Davis, C. J. ; Dell'Oro, S. ; Deninno, M. M. ; Di Domizio, S. ; Di Vacri, M. L. ; Drobizhev, A. ; Fang, D. Q. ; Faverzani, M. ; Ferri, E. ; Ferroni, F. ; Fiorini, E. ; Franceschi, M. A. ; Freedman, S. J. ; Fujikawa, B. K. ; Giachero, A. ; Gironi, L. ; Giuliani, A. ; Gladstone, L. ; Gorla, P. ; Gotti, C. ; Gutierrez, T. D. ; Haller, E. E. ; Han, K. ; Hansen, E. ; Heeger, K. M. ; Hennings-Yeomans, R. ; Huang, H. Z. ; Kadel, R. ; Keppel, G. ; Kolomensky, Yu. G. ; Leder, A. ; Ligi, C. ; Lim, K. E. ; Ma, Y. G. ; Maino, M. ; Marini, L. ; Martinez, M. ; Maruyama, R. H. ; Mei, Y. ; Moggi, N. ; Morganti, S. ; Mosteiro, P. J. ; Napolitano, T. ; Nastasi, M. ; Nones, C. ; Norman, E. B. ; Novati, V. ; Nucciotti, A. ; O'Donnell, T. ; Ouellet, J. L. ; Pagliarone, C. E. ; Pallavicini, M. ; Palmieri, V. ; Pattavina, L. ; Pavan, M. ; Pessina, G. ; Piperno, G. ; Pira, C. ; Pirro, S. ; Pozzi, S. ; Previtali, E. ; Rosenfeld, C. ; Rusconi, C. ; Sakai, M. ; Sangiorgio, S. ; Santone, D. ; Schmidt, B. ; Schmidt, J. ; Scielzo, N. D. ; Singh, V. ; Sisti, M. ; Smith, A. R. ; Taffarello, L. ; Terranova, F. ; Tomei, C. ; Vignati, M. ; Wagaarachchi, S. L. ; Wang, B. S. ; Wang, H. W. ; Welliver, B. ; Wilson, J. ; Winslow, L. A. ; Wise, T. ; Woodcraft, A. ; Zanotti, L. ; Zhang, G. Q. ; Zimmermann, S. ; Zucchelli, S.
The CUORE cryostat and its bolometric detector
Resumen: CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0¿ßß) of 130Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3 mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.
Idioma: Inglés
DOI: 10.1088/1748-0221/12/02/c02055
Año: 2017
Publicado en: Journal of Instrumentation 12 (2017), C02055 [11 pp.]
ISSN: 1748-0221

Factor impacto JCR: 1.258 (2017)
Categ. JCR: INSTRUMENTS & INSTRUMENTATION rank: 44 / 61 = 0.721 (2017) - Q3 - T3
Factor impacto SCIMAGO: 0.642 - Mathematical Physics (Q2) - Instrumentation (Q2)

Tipo y forma: Artículo (PostPrint)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2019-07-09-12:10:13)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2018-08-21, última modificación el 2019-07-09


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)