A rapid magnetic particle-based enzyme immunoassay for human cytomegalovirus glycoprotein B quantification
Resumen: Human cytomegalovirus (HCMV) is a herpes virus that can cause severe infections. Still, the available methods for its diagnostic have the main disadvantage of requiring long time to be performed. In this work, a simple magnetic particle-based enzyme immunoassay (mpEIA) for the quantification of glycoprotein B of Human cytomegalovirus (gB-HCMV) in urine samples is proposed. The immunosensor scheme is based on the analyte protein gB-HCMV sandwiched between a primary monoclonal antibody, (MBs-PrG-mAb1), and a secondary anti-gB-HCMV antibody labelled with Horseradish peroxidase (Ab2-HRP) to allow spectrophotometric detection. The mpEIA analytical performance was tested in urine samples, showing a linear dependence between gB-HCMV concentration and the absorbance signal at 450 nm in a range of concentrations from 90 to 700 pg mL-1. The calculated detection limits for gB-HCMV were 90 ± 2 pg mL-1 and the RSD was about 6.7% in urine samples. The immunosensor showed good selectivity against other viruses from Herpesviridae family, namely varicella zoster and Epstein Barr viruses. The recoveries of spiked human urine samples at 0.30–0.50 ng mL-1 concentration levels of gB-HCMV ranged between 91 to 105%. The proposed mpEIA method was validated following the guidelines of the European Medicines Agency (EMEA-2014), and allows rapid, successful and easy quantification of gB-HCMV in urine samples.
Idioma: Inglés
DOI: 10.1016/j.jpba.2018.04.019
Año: 2018
Publicado en: Journal of Pharmaceutical and Biomedical Analysis 156 (2018), 372-378
ISSN: 0731-7085

Factor impacto JCR: 2.983 (2018)
Categ. JCR: PHARMACOLOGY & PHARMACY rank: 105 / 266 = 0.395 (2018) - Q2 - T2
Categ. JCR: CHEMISTRY, ANALYTICAL rank: 24 / 84 = 0.286 (2018) - Q2 - T1

Factor impacto SCIMAGO: 0.786 - Analytical Chemistry (Q1) - Clinical Biochemistry (Q1) - Spectroscopy (Q1) - Pharmaceutical Science (Q1) - Drug Discovery (Q1)

Financiación: info:eu-repo/grantAgreement/ES/FEDER/POCI-01-0145-007491
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/MUSSEL-RTC-2015-4077-2
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/TEC20013-40561-P
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Química Analítica (Dpto. Química Analítica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2020-01-13-14:52:23)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2019-05-08, última modificación el 2020-01-13


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)