<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
    <record>
        <controlfield tag="001">100782</controlfield>
        <controlfield tag="005">20210319130236.0</controlfield>
        <datafield tag="024" ind1="7" ind2=" ">
            <subfield code="2">doi</subfield>
            <subfield code="a">10.30454/2530-1209.2020.4.3</subfield>
        </datafield>
        <datafield tag="024" ind1="8" ind2=" ">
            <subfield code="2">sideral</subfield>
            <subfield code="a">123404</subfield>
        </datafield>
        <datafield tag="037" ind1=" " ind2=" ">
            <subfield code="a">ART-2020-123404</subfield>
        </datafield>
        <datafield tag="041" ind1=" " ind2=" ">
            <subfield code="a">spa</subfield>
        </datafield>
        <datafield tag="100" ind1=" " ind2=" ">
            <subfield code="a">Ciampi-Dopazzo, JJ</subfield>
        </datafield>
        <datafield tag="245" ind1=" " ind2=" ">
            <subfield code="a">Dispositivo novel para la reducción del TIPS</subfield>
        </datafield>
        <datafield tag="260" ind1=" " ind2=" ">
            <subfield code="c">2020</subfield>
        </datafield>
        <datafield tag="506" ind1="0" ind2=" ">
            <subfield code="a">Access copy available to the general public</subfield>
            <subfield code="f">Unrestricted</subfield>
        </datafield>
        <datafield tag="520" ind1="3" ind2=" ">
            <subfield code="a">En la siguiente nota técnica, después de seleccionar adecuadamente a dos pacientes con shunt portosistémico transyugular (TIPS), que presentaron encefalopatía hepática refractaria a medicamentos y pauta conservadora, se implanto un nuevo dispositivo novedoso para la reducción del TIPS empleando un stent con características específicas (sinus-Reduction Stent Vascular®, Optimed, Ettlingen-Alemania) para la reducción del flujo y mejorar el gradiente portosistémico. El procedimiento se llevo acabo mediante un abordaje transyugular y control angiográfico, donde se procedió a implantar dicho stent para disminuir el flujo sanguíneo del TIPS. El objetivo principal de este estudio fue de conocer el resultado técnico, material empleado y la mejoría del cuadro clínico en estos pacientes.

In the following technical note, after properly selecting two patients with transjugular portosystemic shunt (TIPS), who presented drug-refractory hepatic encephalopathy, a specific new novel device for TIPS reduction using a stent (sinus-Reduction Stent Vascular®, Optimed, Ettlingen-Germany) was implanted to reduce flow and improve the portosystemic gradient. The procedure was carried out through a transjugular approach and angiographic control, where the stent was implanted to reduce the blood flow of the TIPS. The objective of this study was to determine the technical results, describe specific characteristics of of this device, and evaluate the clinical improvement of the patients.</subfield>
        </datafield>
        <datafield tag="540" ind1=" " ind2=" ">
            <subfield code="9">info:eu-repo/semantics/openAccess</subfield>
            <subfield code="a">by-nc-nd</subfield>
            <subfield code="u">http://creativecommons.org/licenses/by-nc-nd/3.0/es/</subfield>
        </datafield>
        <datafield tag="655" ind1=" " ind2="4">
            <subfield code="a">info:eu-repo/semantics/article</subfield>
            <subfield code="v">info:eu-repo/semantics/publishedVersion</subfield>
        </datafield>
        <datafield tag="700" ind1=" " ind2=" ">
            <subfield code="a">Ruiz-Villaverde, G.</subfield>
        </datafield>
        <datafield tag="700" ind1=" " ind2=" ">
            <subfield code="0">(orcid)0000-0002-0113-5121</subfield>
            <subfield code="a">Guirola JA</subfield>
            <subfield code="u">Universidad de Zaragoza</subfield>
        </datafield>
        <datafield tag="700" ind1=" " ind2=" ">
            <subfield code="a">Navarro-Vergara, P.</subfield>
        </datafield>
        <datafield tag="700" ind1=" " ind2=" ">
            <subfield code="0">(orcid)0000-0002-5618-7519</subfield>
            <subfield code="a">Gregorio, Miguel Ángel de</subfield>
            <subfield code="u">Universidad de Zaragoza</subfield>
        </datafield>
        <datafield tag="700" ind1=" " ind2=" ">
            <subfield code="a">Pardo-Moreno, P.</subfield>
        </datafield>
        <datafield tag="710" ind1="2" ind2=" ">
            <subfield code="1">1011</subfield>
            <subfield code="2">770</subfield>
            <subfield code="a">Universidad de Zaragoza</subfield>
            <subfield code="b">Dpto. Microb.Ped.Radio.Sal.Pú.</subfield>
            <subfield code="c">Área Radiol. y Medicina Física</subfield>
        </datafield>
        <datafield tag="773" ind1=" " ind2=" ">
            <subfield code="g">20, 4 (2020), 34-46</subfield>
            <subfield code="p">Intervencionismo</subfield>
            <subfield code="t">Intervencionismo</subfield>
            <subfield code="x">1697-8544</subfield>
        </datafield>
        <datafield tag="856" ind1="4" ind2="1">
            <subfield code="u">http://revistaintervencionismo.com/intervencionismo/dispositivo-novel-para-la-reduccion-del-tips/</subfield>
            <subfield code="z">Texto completo de la revista</subfield>
        </datafield>
        <datafield tag="856" ind1="4" ind2=" ">
            <subfield code="s">763700</subfield>
            <subfield code="u">http://zaguan.unizar.es/record/100782/files/texto_completo.pdf</subfield>
            <subfield code="y">Versión publicada</subfield>
        </datafield>
        <datafield tag="856" ind1="4" ind2=" ">
            <subfield code="s">1207996</subfield>
            <subfield code="u">http://zaguan.unizar.es/record/100782/files/texto_completo.jpg?subformat=icon</subfield>
            <subfield code="x">icon</subfield>
            <subfield code="y">Versión publicada</subfield>
        </datafield>
        <datafield tag="909" ind1="C" ind2="O">
            <subfield code="o">oai:zaguan.unizar.es:100782</subfield>
            <subfield code="p">articulos</subfield>
            <subfield code="p">driver</subfield>
        </datafield>
        <datafield tag="951" ind1=" " ind2=" ">
            <subfield code="a">2021-03-19-11:12:55</subfield>
        </datafield>
        <datafield tag="980" ind1=" " ind2=" ">
            <subfield code="a">ARTICLE</subfield>
        </datafield>
    </record>

    
</collection>