000112185 001__ 112185
000112185 005__ 20240319080957.0
000112185 0247_ $$2doi$$a10.3390/jcm11051216
000112185 0248_ $$2sideral$$a128099
000112185 037__ $$aART-2022-128099
000112185 041__ $$aeng
000112185 100__ $$aDíaz Barreda, M. D.
000112185 245__ $$aModification of corneal biomechanics and intraocular pressure following non-penetrating deep sclerectomy
000112185 260__ $$c2022
000112185 5060_ $$aAccess copy available to the general public$$fUnrestricted
000112185 5203_ $$aChanges in the cornea can influence outcomes in patients with primary open-angle glaucoma (POAG). We aimed to evaluate the relevance of changes in corneal biomechanics and intraocular pressure (IOP) in patients undergoing non-penetrating deep sclerectomy (NPDS) with the Esnoper V2000 implant® (AJL Ophthalmic S.A., Gasteiz, Spain). We included 42 eyes of 42 patients with POAG scheduled for NPDS with the Esnoper V2000 implant. Biomechanical properties were measured by Ocular Response Analyzer® G3 (ORA; Reichert Inc., Depew, NY, USA). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated IOP (IOPcc), and Goldmann-correlated IOP (IOPg) were measured the day before surgery and on day 1, 7, and 30 and 2 and 3 months after surgery. CH initially increased, fell below the presurgical value at 30 days after the surgery, and increased again at 2 and 3 months. CRF, IOPcc, and IOPg decreased on the first day after surgery, then followed a trend of increasing but stayed below pre-surgery levels. All values reached statistical significance. While observed changes in corneal biomechanics after NPDS and Esnoper V2000 implant were significant, more studies are needed if we are to understand their influence on corneal biomechanics and their clinical relevance in POAG.
000112185 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000112185 590__ $$a3.9$$b2022
000112185 592__ $$a0.935$$b2022
000112185 591__ $$aMEDICINE, GENERAL & INTERNAL$$b58 / 169 = 0.343$$c2022$$dQ2$$eT2
000112185 593__ $$aMedicine (miscellaneous)$$c2022$$dQ1
000112185 594__ $$a5.4$$b2022
000112185 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000112185 700__ $$aSánchez Marín, I.
000112185 700__ $$aBoned Murillo, A.
000112185 700__ $$aPérez Navarro, I.
000112185 700__ $$aMartínez, J.
000112185 700__ $$0(orcid)0000-0002-4406-1791$$aPardina-Claver, E.$$uUniversidad de Zaragoza
000112185 700__ $$aPérez, D.
000112185 700__ $$0(orcid)0000-0001-9876-5850$$aAscaso, F. J.$$uUniversidad de Zaragoza
000112185 700__ $$aIbáñez, J.
000112185 7102_ $$11013$$2646$$aUniversidad de Zaragoza$$bDpto. Cirugía$$cÁrea Oftalmología
000112185 773__ $$g11, 5 (2022), 1216 [10 pp.]$$pJ. clin.med.$$tJournal of Clinical Medicine$$x2077-0383
000112185 8564_ $$s533209$$uhttps://zaguan.unizar.es/record/112185/files/texto_completo.pdf$$yVersión publicada
000112185 8564_ $$s2871946$$uhttps://zaguan.unizar.es/record/112185/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000112185 909CO $$ooai:zaguan.unizar.es:112185$$particulos$$pdriver
000112185 951__ $$a2024-03-18-13:48:31
000112185 980__ $$aARTICLE