000117648 5203_ $$aPeople with lower limb amputation present greater displacements of their centre of gravity in a static situation than able-bodied individuals, as they depend on visual information to a greater extent, which implies an altered stability pattern. The efficacy of different hardness of plantar support to help maintain stability has not yet been determined. The aim of the present study is to assess stability in people with unilateral transtibial amputation with prosthesis in a static situation with insoles of different degrees of hardness and visual conditions with respect to the able-bodied population. For this purpose, 25 patients with amputation and 25 able-bodied individuals were included in both groups, postural stability was assessed by stabilometry. This assessment was carried out under normal conditions (on the floor of the dynamometric platform with eyes open), and under altered conditions (with the interposition of different materials such as plantar support: rigid and soft insoles and, eyes shut). Three variables were considered to assess stability: length of movement of the barycenter (mm), lateral velocity (mm/sg) and anterior velocity (mm/sg). All of them were analysed with the patient in static on the dynamometric platform. The results showed statistically significant differences between the two groups, (amputees and controls) with less stability in the amputee group (p < 0.05) when analysing the variables of length of movement of the barycenter, lateral velocity and anterior velocity. Amputee patients with open eyes exhibited greater stability than those with closed eyes. The hard insoles improved the stability data in amputees (length of movement of the barycenter and anterior velocity) with respect to the barefoot condition, and the soft insoles showed less stability than the patients with hard insoles, or than the barefoot patients. From the results obtained in this study, we can conclude that the PP-DWST 4 mm rigid insoles improve static stability in people with amputation. However, soft insoles impair stability and are therefore discouraged.
000117648 536__ $$9info:eu-repo/grantAgreement/ES/MINECO/PID2019-108009RB-l00
000117648 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000117648 590__ $$a4.6$$b2022
000117648 592__ $$a0.973$$b2022
000117648 591__ $$aMULTIDISCIPLINARY SCIENCES$$b22 / 73 = 0.301$$c2022$$dQ2$$eT1
000117648 593__ $$aMultidisciplinary$$c2022$$dQ1
000117648 594__ $$a7.5$$b2022
000117648 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000117648 700__ $$0(orcid)0000-0003-4071-1467$$aLuesma, Maria Jose$$uUniversidad de Zaragoza
000117648 700__ $$aValero, Jose
000117648 700__ $$aPilar del Caso, Maria
000117648 700__ $$aAlonso, Cristina
000117648 700__ $$aCalleja, Jorge
000117648 700__ $$aLorenzo, Tania
000117648 700__ $$0(orcid)0000-0001-5505-6974$$aBayod, Javier$$uUniversidad de Zaragoza
000117648 700__ $$0(orcid)0000-0002-0595-719X$$aLahoz, Manuel$$uUniversidad de Zaragoza
000117648 7102_ $$11003$$2027$$aUniversidad de Zaragoza$$bDpto. Anatom.Histolog.Humanas$$cArea Anatom.Embriol.Humana
000117648 7102_ $$15004$$2605$$aUniversidad de Zaragoza$$bDpto. Ingeniería Mecánica$$cÁrea Mec.Med.Cont. y Teor.Est.
000117648 773__ $$g12, 1 (2022), 7854 [10 pp]$$pSci. rep. (Nat. Publ. Group)$$tScientific reports (Nature Publishing Group)$$x2045-2322
000117648 8564_ $$s1090648$$uhttps://zaguan.unizar.es/record/117648/files/texto_completo.pdf$$yVersión publicada
000117648 8564_ $$s2600701$$uhttps://zaguan.unizar.es/record/117648/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000117648 909CO $$ooai:zaguan.unizar.es:117648$$particulos$$pdriver
000117648 951__ $$a2024-03-18-15:33:14
000117648 980__ $$aARTICLE