Biomechanical evaluation of syndesmotic fixation techniques via finite element analysis: Screw vs. suture button
Resumen: Background and Objective: Tibiofibular syndesmotic injuries may cause degenerative changes, reduction in ankle function and compromising ankle stability. Different fixation techniques try to restore its functionality. Screw-fixation is the gold-standard. Recently, suture-button fixation has aroused the attention because it allows for physiologic micromotion while maintaining an accurate reduction. The aim of this study is to compare the biomechanical behaviour of both fixation techniques using the finite element method. Methods: A three-dimensional finite element model of the tibiofibular joint was reconstructed simulating the intact ankle and the injured syndesmosis. Then, different methods of syndesmosis fixation were analysed: screws (number of cortices, number of screws and distance between screws) and suture buttons (single, double parallel and double divergent with a sensitivity analysis on the pretension forces) configuration. Ligaments and cartilages were included and simulated as spring elements. Physiological loads during stance phase were simulated. Results: Syndesmosis widening and von Mises stresses were computed. Syndesmosis widening in the injured configuration compromised joint stability (2.06 mm), whereas using a single quadricortical screw (0.18 mm) stiffened the joint. Syndesmosis widening using suture-buttons were closer to syndesmosis widening of the intact ankle configuration (0.97 mm). Von Mises stresses were higher for the titanium screws than for the suture buttons. Conclusions: A detailed biomechanical comparison among different syndesmotic fixation was performed. Suture buttons have advantages with regard to syndesmosis widening in comparison to screw fixation. This fact supports the good long-term clinical results obtained with suture buttons fixation. The proposed methodology could be an efficient tool for preoperative planning.
Idioma: Inglés
DOI: 10.1016/j.cmpb.2021.106272
Año: 2021
Publicado en: Computer Methods and Programs in Biomedicine 208 (2021), 106272 [7 pp.]
ISSN: 0169-2607

Factor impacto JCR: 7.027 (2021)
Categ. JCR: COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS rank: 20 / 112 = 0.179 (2021) - Q1 - T1
Categ. JCR: MEDICAL INFORMATICS rank: 6 / 31 = 0.194 (2021) - Q1 - T1
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 20 / 98 = 0.204 (2021) - Q1 - T1
Categ. JCR: COMPUTER SCIENCE, THEORY & METHODS rank: 12 / 111 = 0.108 (2021) - Q1 - T1

Factor impacto CITESCORE: 9.7 - Medicine (Q1) - Computer Science (Q1)

Factor impacto SCIMAGO: 1.329 - Health Informatics (Q1) - Computer Science Applications (Q1)

Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2017-84780-C2-1-R
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Traumatología y Ortopedia (Dpto. Cirugía)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2023-05-18-14:55:20)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Mec. de Medios Contínuos y Teor. de Estructuras
Artículos > Artículos por área > Traumatología y Ortopedia



 Registro creado el 2022-07-15, última modificación el 2023-05-19


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)