000117747 001__ 117747
000117747 005__ 20220725102147.0
000117747 037__ $$aTAZ-TFM-2022-093
000117747 041__ $$aeng
000117747 1001_ $$aSuárez Casiano, Raúl
000117747 24200 $$aDesign and fabrication of bone-on-chip microfluidic devices for cell culture.
000117747 24500 $$aDesign and fabrication of bone-on-chip microfluidic devices for cell culture.
000117747 260__ $$aZaragoza$$bUniversidad de Zaragoza$$c2022
000117747 506__ $$aby-nc-sa$$bCreative Commons$$c3.0$$uhttp://creativecommons.org/licenses/by-nc-sa/3.0/
000117747 520__ $$aThis project aimed to provide a basis for the development of a bottom up assembly of tissue within a microfluidic chip for a bone-on-a-chip model. The main purpose of the project was erforming a cell culture in which human adipose-derived stem cells (“hASCs") spheroids could grow inside of the central channel of the device without invading the side channels. Concretely, highly porous buckyball microscaffolds, fabricated via two-photon polymerization technique, were employed as a structure to support the delivery of spheroids into the microfluidic device. The vertical central inlet (“VCI”) “SLA Accura® Xtreme™” mould was the best solution for the fabrication of the microfluidic devices in terms of surface quality and additionally because no leaking was observed during the test process. The cell culture results showed that the central channel was not completely filled with spheroids due to the presence of air bubbles that were going inside the device during the pipetting. Additionally, cells were also growing inside the side channels which was not desired. The side channels are necessary for perfusion of nutrients, growth factors etc. Live/dead staining resultsshowed that cells were still alive after 7 days of cell culture, which means that the protocol could be useful for further long-term culture studies like differentiation of stem cells into osteoblast cells. Considering the mentioned results, another method for introducing the spheroids inside the microfluidic device must be chosen. As future lines of investigation, more cell culture experiments should be done to verify if it is possible to completely fill the central channel with spheroids and create bone tissue inside without penetrating the side channels. Moreover, surface coating of the microfluidic devices could be performed to prevent cell attachment.<br />
000117747 521__ $$aMáster Universitario en Ingeniería Biomédica
000117747 540__ $$aDerechos regulados por licencia Creative Commons
000117747 700__ $$aOvsianikov, Aleksandr$$edir.
000117747 7102_ $$aUniversidad de Zaragoza$$bIngeniería Mecánica$$cMec. de Medios Contínuos y Teor. de Estructuras
000117747 7202_ $$aGarcía Aznar, José Manuel$$eponente
000117747 8560_ $$f822230@unizar.es
000117747 8564_ $$s22052716$$uhttps://zaguan.unizar.es/record/117747/files/TAZ-TFM-2022-093.pdf$$yMemoria (eng)
000117747 909CO $$ooai:zaguan.unizar.es:117747$$pdriver$$ptrabajos-fin-master
000117747 950__ $$a
000117747 951__ $$adeposita:2022-07-25
000117747 980__ $$aTAZ$$bTFM$$cEINA
000117747 999__ $$a20220509131952.CREATION_DATE