Corneal tissue changes following short-term soft contact lens wear of different materials
Resumen: Purpose: To study the effect of different soft contact lens (CL) materials during short-term wear on corneal tissue. Methods: Twenty-two healthy participants wore both silicone hydrogel (MyDay, CooperVision) and hydrogel soft CLs (Biomedics 1 day extra, CooperVision) for 8 h per lens. In each session, Scheimpflug images were captured before and immediately after CL removal. Images were analysed using the densitometry distribution analysis, a technique from which two parameters, α (corneal transparency) and β (corneal homogeneity), were estimated. In addition, the central corneal thickness changes after CL wear and the influence of the CL material on corneal transparency were evaluated. Results: The β parameter (homogeneity) increased by 5% after wearing both CL materials (paired t-test, p < 0.001). However, the α parameter (transparency) only increased in half of the participants. No material was found to be more determinant in causing the corneal densitometry changes. Statistically significant but not clinically relevant changes in corneal thickness were observed. Conclusions: Biomarkers of corneal tissue integrity (α and β) were affected by short-term soft contact lens wear. The observed changes in corneal transparency and homogeneity were not clinically relevant but support the importance of participant-material biocompatibility.
Idioma: Inglés
DOI: 10.1111/opo.13067
Año: 2023
Publicado en: OPHTHALMIC AND PHYSIOLOGICAL OPTICS 43, 1 (2023), 35-45
ISSN: 0275-5408

Factor impacto JCR: 2.8 (2023)
Categ. JCR: OPHTHALMOLOGY rank: 24 / 95 = 0.253 (2023) - Q2 - T1
Factor impacto CITESCORE: 5.1 - Ophthalmology (Q1) - Optometry (Q1) - Sensory Systems (Q2)

Factor impacto SCIMAGO: 1.162 - Ophthalmology (Q1) - Sensory Systems (Q1) - Optometry (Q1)

Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Física Aplicada (Dpto. Física Aplicada)
Área (Departamento): Área Óptica (Dpto. Física Aplicada)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2024-11-22-11:57:49)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Física Aplicada
Artículos > Artículos por área > Optica



 Registro creado el 2023-01-11, última modificación el 2024-11-25


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)