000126992 5203_ $$aIn this paper a novel analytical design methodology for wind power permanent magnet synchronous generators is presented. This kind of electric generator plays a major role in small-scale wind energy conversion systems up to 10 kW. The proposed diameter-cubed sizing equation is based both on the generator requirements, imposed by the application, and the design parameters that rely on the designer criteria. The magnetic field waveforms of both the permanent magnets field and the armature field are considered from the first moment through the winding factors, as well as the slots effects given by the Carter factor. The analytical model of the permanent magnet synchronous generator is validated with the finite element method, showing good agreement, both with no load and under load. As the generator is unsaturated, the main source of divergence between the analytical and the finite element model are the iron losses, due to the nonuniform magnetic field distribution.
000126992 536__ $$9info:eu-repo/grantAgreement/EUR/AEI/TED2021-129801B-I00$$9info:eu-repo/grantAgreement/ES/MCIU/FPU20/03436
000126992 540__ $$9info:eu-repo/semantics/openAccess$$aby-nc-nd$$uhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
000126992 592__ $$a0.152$$b2023
000126992 593__ $$aElectrical and Electronic Engineering$$c2023$$dQ4
000126992 593__ $$aRenewable Energy, Sustainability and the Environment$$c2023$$dQ4
000126992 593__ $$aEnergy Engineering and Power Technology$$c2023$$dQ4
000126992 594__ $$a0.7$$b2023
000126992 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000126992 700__ $$0(orcid)0000-0001-7764-235X$$aArtal-Sevil, J.S.$$uUniversidad de Zaragoza
000126992 700__ $$0(orcid)0000-0002-4770-0069$$aDomínguez-Navarro, J.A.$$uUniversidad de Zaragoza
000126992 7102_ $$15009$$2535$$aUniversidad de Zaragoza$$bDpto. Ingeniería Eléctrica$$cÁrea Ingeniería Eléctrica
000126992 773__ $$g21, 1 (2023), 606-612$$pRenewable energy power qual. j.$$tRenewable Energy and Power Quality Journal$$x2172-038X
000126992 8564_ $$s2607816$$uhttps://zaguan.unizar.es/record/126992/files/texto_completo.pdf$$yVersión publicada
000126992 8564_ $$s2732306$$uhttps://zaguan.unizar.es/record/126992/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000126992 909CO $$ooai:zaguan.unizar.es:126992$$particulos$$pdriver
000126992 951__ $$a2024-07-31-09:55:45
000126992 980__ $$aARTICLE