000127028 001__ 127028
000127028 005__ 20241125101156.0
000127028 0247_ $$2doi$$a10.1111/opo.13211
000127028 0248_ $$2sideral$$a134331
000127028 037__ $$aART-2023-134331
000127028 041__ $$aeng
000127028 100__ $$0(orcid)0000-0001-5186-1837$$aConsejo, Alejandra$$uUniversidad de Zaragoza
000127028 245__ $$aRelationship between corneal tissue and shape in short-term soft contact lens wear
000127028 260__ $$c2023
000127028 5060_ $$aAccess copy available to the general public$$fUnrestricted
000127028 5203_ $$aAbstractPurposeTo investigate which morphometric and ocular surface tissue parameters are affected by short‐term soft contact lens (CL) wear and to assess whether they carry related or independent information.MethodsTwenty‐two healthy participants wore silicone hydrogel (SiHy; MyDay, CooperVision) soft CLs for 8 h in their left eye. Corneal tomography and corneoscleral topography were captured before and immediately after CL wear. Central corneal thickness (CCT), corneoscleral parameters (limbus position and corneoscleral junction [CSJ] angle) and corneal tissue parameters (corneal transparency and homogeneity) were evaluated.ResultsCorneoscleral parameters (limbus position and CSJ angle) were independent of corneal tissue parameters (transparency and homogeneity) at baseline and after CL wear. CCT was independent of all the other parameters examined at baseline, but baseline values of corneal tissue parameters were moderately correlated with CCT change (transparency: r = −0.51; p = 0.007), homogeneity: r = −0.46; p = 0.02).ConclusionsA complete characterisation of ocular surface changes following CL wear should consider corneoscleral topography and corneal densitometry simultaneously, since they carry complementary information.
000127028 536__ $$9info:eu-repo/grantAgreement/EUR/MICINN/TED2021-130723A-I00$$9info:eu-repo/grantAgreement/ES/MICIU/PID2020-114311RA-I00
000127028 540__ $$9info:eu-repo/semantics/openAccess$$aby-nc-nd$$uhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
000127028 590__ $$a2.8$$b2023
000127028 592__ $$a1.162$$b2023
000127028 591__ $$aOPHTHALMOLOGY$$b24 / 95 = 0.253$$c2023$$dQ2$$eT1
000127028 593__ $$aOphthalmology$$c2023$$dQ1
000127028 593__ $$aSensory Systems$$c2023$$dQ1
000127028 593__ $$aOptometry$$c2023$$dQ1
000127028 594__ $$a5.1$$b2023
000127028 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000127028 700__ $$aRoman, Denisa M.
000127028 700__ $$aRoll, Vanesa
000127028 700__ $$0(orcid)0000-0002-3979-4528$$aRemon, Laura$$uUniversidad de Zaragoza
000127028 7102_ $$12002$$2385$$aUniversidad de Zaragoza$$bDpto. Física Aplicada$$cÁrea Física Aplicada
000127028 7102_ $$12002$$2647$$aUniversidad de Zaragoza$$bDpto. Física Aplicada$$cÁrea Óptica
000127028 773__ $$g43, 6 (2023), 1372-1378$$pOphthalmic physiol. opt.$$tOPHTHALMIC AND PHYSIOLOGICAL OPTICS$$x0275-5408
000127028 8564_ $$s1152513$$uhttps://zaguan.unizar.es/record/127028/files/texto_completo.pdf$$yVersión publicada
000127028 8564_ $$s2563410$$uhttps://zaguan.unizar.es/record/127028/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000127028 909CO $$ooai:zaguan.unizar.es:127028$$particulos$$pdriver
000127028 951__ $$a2024-11-22-12:09:36
000127028 980__ $$aARTICLE