000132472 001__ 132472
000132472 005__ 20240311111225.0
000132472 0247_ $$2doi$$a10.1016/j.dibe.2024.100326
000132472 0248_ $$2sideral$$a137628
000132472 037__ $$aART-2024-137628
000132472 041__ $$aeng
000132472 100__ $$0(orcid)0000-0003-4278-6622$$aPérez-Bella, José M.$$uUniversidad de Zaragoza
000132472 245__ $$aIncorporating façade-specific climatic factors to improve the ISO 15927-3 characterisation of wind-driven rain spells: Dutch and Spanish case studies
000132472 260__ $$c2024
000132472 5060_ $$aAccess copy available to the general public$$fUnrestricted
000132472 5203_ $$aISO standard 15927-3 characterise episodic exposures of wind-driven rain (WDR) on building façades by identifying wetting intervals, referred to as spells. Spells separated by 96 h or more without WDR are considered, assuming that this interval is sufficient for evaporative losses to exceed prior rainwater gains. This approach ignores variations in evaporation due to the façade orientation and local environmental factors, which cause diverse drying intervals even for the same material. This study proposes an estimation of potential evaporation losses in façades, considering their orientation and local climate. Representative drying intervals and enhanced façade-specific WDR spells are identified by combining potential evaporation losses with the directional WDR exposure. The results at locations in The Netherlands and Spain demonstrates that the drying intervals can vary significantly depending on these factors (regardless of the surface materials), which suggests reconsidering the current 96-h ISO model to minimise uncertainties when characterising episodic WDR exposures.
000132472 536__ $$9info:eu-repo/grantAgreement/ES/MICINN/PID2021-122203OB-I00
000132472 540__ $$9info:eu-repo/semantics/openAccess$$aby-nc-nd$$uhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
000132472 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000132472 700__ $$0(orcid)0000-0002-3776-9791$$aDomínguez-Hernández, Javier$$uUniversidad de Zaragoza
000132472 700__ $$0(orcid)0000-0003-0785-4132$$aIbarz-Montaner, Elena$$uUniversidad de Zaragoza
000132472 700__ $$0(orcid)0000-0001-5634-9357$$aOrna-Carmona, Martín
000132472 700__ $$0(orcid)0000-0002-1342-8482$$aSalesa-Bordanaba, Ángel
000132472 700__ $$aOrr, Scott A.
000132472 7102_ $$15004$$2510$$aUniversidad de Zaragoza$$bDpto. Ingeniería Mecánica$$cArea Ingeniería Construcción
000132472 7102_ $$15004$$2605$$aUniversidad de Zaragoza$$bDpto. Ingeniería Mecánica$$cÁrea Mec.Med.Cont. y Teor.Est.
000132472 773__ $$g17 (2024), 100326 [18 pp.]$$tDevelopments in the Built Environment$$x2666-1659
000132472 8564_ $$s4305487$$uhttps://zaguan.unizar.es/record/132472/files/texto_completo.pdf$$yVersión publicada
000132472 8564_ $$s2743390$$uhttps://zaguan.unizar.es/record/132472/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000132472 909CO $$ooai:zaguan.unizar.es:132472$$particulos$$pdriver
000132472 951__ $$a2024-03-11-09:52:02
000132472 980__ $$aARTICLE