000146966 001__ 146966
000146966 005__ 20251004074220.0
000146966 0247_ $$2doi$$a10.52152/D11173
000146966 0248_ $$2sideral$$a140796
000146966 037__ $$aART-2024-140796
000146966 041__ $$aeng
000146966 100__ $$aPolo Royo, Marco
000146966 245__ $$aIs my balance disorder patient improving with this rehabilitation treatment? Rapid stabilometric platform test
000146966 260__ $$c2024
000146966 5060_ $$aAccess copy available to the general public$$fUnrestricted
000146966 5203_ $$aThe aim of the present study is to compare the use and results of a rapid stabilometric platform test with traditional clinical scales to assess the individual clinical evolution of heterogeneous patients with balance disorders during rehabilitation treatment. The 67 participating vertigo patients underwent two assessment sessions, one before starting rehabilitation treatment and one after starting treatment. In each session, six static balance assessment tests with the stabilometric platform were accomplished. Then, the centre of pressure (COP) measured by the device, was processed using the MCQ-Balance method, that transforms the signal into clinical interpretable results. Additionally, in order to compare the results, three medical diagnostic tests were conducted and a methodical flag system to classify their results was proposed. The agreement rises until 85.71% with a contingency coefficient of 0.751 and a Kappa of 0.775. The platform showed a sensitivity of 100% with a specificity of 72.99%. Furthermore, it was not found false negatives in the platform. The stabilometric platform provided valuable assistance in the diagnosis of the evolution of balance pathology, involving less time and uncertainty than traditional tests.
000146966 540__ $$9info:eu-repo/semantics/openAccess$$aby-sa$$uhttps://creativecommons.org/licenses/by-sa/4.0/deed.es
000146966 590__ $$a0.7$$b2024
000146966 592__ $$a0.153$$b2024
000146966 591__ $$aENGINEERING, MULTIDISCIPLINARY$$b122 / 175 = 0.697$$c2024$$dQ3$$eT3
000146966 593__ $$aEngineering (miscellaneous)$$c2024$$dQ4
000146966 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000146966 700__ $$0(orcid)0000-0001-8737-5814$$aTorre Pardos, Juan de la
000146966 700__ $$0(orcid)0000-0003-4527-3267$$aMarin Boné, Javier$$uUniversidad de Zaragoza
000146966 700__ $$0(orcid)0000-0003-3223-1324$$aMarin Zurdo, José Javier$$uUniversidad de Zaragoza
000146966 700__ $$0(orcid)0000-0002-7876-4735$$aGómez Trullén, Eva María$$uUniversidad de Zaragoza
000146966 7102_ $$11006$$2245$$aUniversidad de Zaragoza$$bDpto. Fisiatría y Enfermería$$cÁrea Educación Física y Depor.
000146966 7102_ $$15002$$2720$$aUniversidad de Zaragoza$$bDpto. Ingeniería Diseño Fabri.$$cÁrea Proyectos de Ingeniería
000146966 773__ $$g99, 5 (2024), 475-480$$pDyna (Bilbao)$$tDyna (Bilbao)$$x0012-7361
000146966 8564_ $$s679734$$uhttps://zaguan.unizar.es/record/146966/files/texto_completo.pdf$$yVersión publicada$$zinfo:eu-repo/date/embargoEnd/2025-01-31
000146966 8564_ $$s2524816$$uhttps://zaguan.unizar.es/record/146966/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada$$zinfo:eu-repo/date/embargoEnd/2025-01-31
000146966 909CO $$ooai:zaguan.unizar.es:146966$$particulos$$pdriver
000146966 951__ $$a2025-10-02-15:14:15
000146966 980__ $$aARTICLE