Resumen: We present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass. Idioma: Inglés DOI: 10.1016/j.nima.2024.170075 Año: 2024 Publicado en: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1071 [14 pp.] (2024), 170075 ISSN: 0168-9002 Factor impacto JCR: 1.4 (2024) Categ. JCR: INSTRUMENTS & INSTRUMENTATION rank: 57 / 79 = 0.722 (2024) - Q3 - T3 Categ. JCR: PHYSICS, PARTICLES & FIELDS rank: 21 / 31 = 0.677 (2024) - Q3 - T3 Categ. JCR: PHYSICS, NUCLEAR rank: 15 / 22 = 0.682 (2024) - Q3 - T3 Categ. JCR: NUCLEAR SCIENCE & TECHNOLOGY rank: 24 / 41 = 0.585 (2024) - Q3 - T2 Factor impacto SCIMAGO: 0.451 - Nuclear and High Energy Physics (Q2) - Instrumentation (Q2)