Accuracy of the standard and distal-to-proximal sequence of the upper limb neurodynamic test 1 for the diagnosis of carpal tunnel syndrome: the role of side-to-side comparisons
Resumen: Background/Objective: This study aimed to evaluate the diagnostic accuracy of two upper limb neurodynamic test 1 (ULNT1) sequences for detecting carpal tunnel syndrome (CTS) in patients with unilateral symptoms. The standard sequence (ULNT1-STD) and a distal-to-proximal sequence (ULNT1-DIST) were investigated. A local-initiated sequence may facilitate symptoms reproduction in CTS, and comparing the affected side with the unaffected side could improve the detection of altered median nerve mechanosensitivity when symptoms are not directly reproduced. Methods: A total of 134 consecutive patients with clinically suspected unilateral CTS were recruited. Nerve conduction studies were used as a reference test. Results: When considering only symptom reproduction as the criterion for a positive test, ULNT1-STD showed a sensitivity of 0.398 and a specificity of 0.780 (positive likelihood ratio [+LR]: 1.81; negative likelihood ratio [−LR]: 0.77); whereas ULNT1-DIST demonstrated a sensitivity of 0.548 with a specificity of 0.732 (+LR: 2.04; −LR: 0.62). When a positive test was defined by symptom reproduction or inter-limb asymmetry (in range of motion or sensory response), ULNT1-STD showed an improved sensitivity of 0.613 but a reduced specificity of 0.537 (+LR: 1.32; −LR: 0.72). In comparison, ULNT1-DIST increased its sensitivity to 0.871 with a specificity of 0.683 (+LR: 2.75; −LR: 0.19). Conclusions: ULNT1-DIST offers better diagnostic accuracy for CTS compared to the ULNT1-STD sequence, especially when interlimb asymmetries in range of motion or sensory response are considered. However, side-to-side comparisons have reduced utility in cases with bilateral symptoms, limiting their application in clinical practice.
Idioma: Inglés
DOI: 10.3390/jcm13237122
Año: 2024
Publicado en: Journal of Clinical Medicine 13, 23 (2024), 7122 [17 pp.]
ISSN: 2077-0383

Factor impacto JCR: 2.9 (2024)
Categ. JCR: MEDICINE, GENERAL & INTERNAL rank: 65 / 332 = 0.196 (2024) - Q1 - T1
Factor impacto SCIMAGO: 0.919 - Medicine (miscellaneous) (Q1)

Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Area Anatom.Embriol.Humana (Dpto. Anatom.Histolog.Humanas)
Área (Departamento): Área Fisioterapia (Dpto. Fisiatría y Enfermería)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2025-09-22-14:49:25)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Anatomía y Embriología Humana
Artículos > Artículos por área > Fisioterapia



 Registro creado el 2025-01-08, última modificación el 2025-09-23


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)