Validity and Reliability of Kinovea® for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion
Resumen: The anatomy of the pelvis may obscure differences in pelvic tilt, potentially underestimating its correlation with clinical measures. Measuring the total sagittal range of pelvic movement can serve as a reliable indicator of pelvic function. This study assessed the inter- and intra-examiner reliability of the Kinovea® version 0.9.5 and its agreement with the Qualisys System (3D motion capture) for measuring the total pelvic range of movement (ROM) in the sagittal plane, establishing Kinovea®’s validity in standing and sitting positions with 45° of hip flexion. A cross-sectional study was conducted with 13 asymptomatic participants. Pelvic kinematics were recorded using both systems. Pelvic posture, anterior and posterior tilt, and total pelvic ROM in the sagittal plane were analyzed. The Intraclass Correlation Coefficient (ICC) was used to evaluate reliability and validity. Additionally, the technical error of measurement (TEM), relative TEM, standard error of measurement, and minimal detectable change (MDC) were calculated to establish Kinovea®’s accuracy. Kinovea® demonstrated excellent inter- and intra-examiner reliability for total pelvic ROM in standing and sitting measurements (ICC > 0.90), with relative TEM values below 10% and MDC values between 1.60°and 11.20°. Validity showed good-to-excellent ICC values when comparing Kinovea® and the Qualisys System. This finding suggests that Kinovea® is a valid tool for obtaining reproducible measurements of total pelvic ROM in the sagittal plane in standing and sitting positions, demonstrating excellent-to-good inter- and intra-examiner reliability for pelvic kinematics.
Idioma: Inglés
DOI: 10.3390/s25010250
Año: 2025
Publicado en: Sensors 25, 1 (2025), 250 [13 pp.]
ISSN: 1424-8220

Financiación: info:eu-repo/grantAgreement/ES/DGA-CUS/621-2023
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Area Anatom.Embriol.Humana (Dpto. Anatom.Histolog.Humanas)
Área (Departamento): Área Fisioterapia (Dpto. Fisiatría y Enfermería)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2025-10-09-13:25:50)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Anatomía y Embriología Humana
Artículos > Artículos por área > Fisioterapia



 Registro creado el 2025-01-20, última modificación el 2025-10-09


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)