<?xml version="1.0" encoding="UTF-8"?>
<collection>
<dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:invenio="http://invenio-software.org/elements/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:identifier>doi:10.1109/AMPS.2019.8897762</dc:identifier><dc:language>eng</dc:language><dc:creator>Lodetti, S.</dc:creator><dc:creator>Khokhlov, V.</dc:creator><dc:creator>Meyer, J.</dc:creator><dc:creator>Bruna, Jorge</dc:creator><dc:creator>Melero, Julio J.</dc:creator><dc:title>A robust measurement method for supraharmonics under power frequency deviations</dc:title><dc:identifier>ART-2019-115915</dc:identifier><dc:description>This paper introduces a new measurement method for supraharmonic distortion with improved robustness against power frequency deviations. The proposed method is based on wavelet analysis and it is designed to analyze a 10 cycles measurement interval. Fourier-based methods, instead, must analyze a fixed 200 ms window in order to avoid apparent shifts of the supraharmonic frequency components. The results of the experimental measurements presented in the paper show that the Fourier-based method suggested in IEC 61000-4-7 standard produces results affected by the value of the power frequency. The proposed method, instead, provides results completely independent of the power frequency. This feature also removes the need of a previous high pass filtering stage, required for the IEC method. Moreover, the proposed method has the additional advantage of working on the same measurement interval as traditional harmonics (below 2 kHz), feature that can reduce the complexity of measurement instruments.</dc:description><dc:date>2019</dc:date><dc:source>http://zaguan.unizar.es/record/161021</dc:source><dc:doi>10.1109/AMPS.2019.8897762</dc:doi><dc:identifier>http://zaguan.unizar.es/record/161021</dc:identifier><dc:identifier>oai:zaguan.unizar.es:161021</dc:identifier><dc:relation>info:eu-repo/grantAgreement/EC/H2020/676042/EU/Metrology Excellence Academic Network for Smart Grids/MEAN4SG</dc:relation><dc:relation>This project has received funding from the European Union’s Horizon 2020 research and innovation program under grant agreement No H2020 676042-MEAN4SG</dc:relation><dc:identifier.citation>IEEE International Workshop on Applied Measurements for Power Systems proceedings (2019), 19154205  [6 pp.]</dc:identifier.citation><dc:rights>All rights reserved</dc:rights><dc:rights>http://www.europeana.eu/rights/rr-f/</dc:rights><dc:rights>info:eu-repo/semantics/openAccess</dc:rights></dc:dc>

</collection>