<?xml version="1.0" encoding="UTF-8"?>
<collection>
<dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:invenio="http://invenio-software.org/elements/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:identifier>doi:10.1080/01652176.2025.2532396</dc:identifier><dc:language>eng</dc:language><dc:creator>Marteles, Diana</dc:creator><dc:creator>Lebrero, María Eugenia</dc:creator><dc:creator>Villanueva-Saz, Sergio</dc:creator><dc:creator>Esteban Sanz, Clara</dc:creator><dc:creator>Martín, Víctor</dc:creator><dc:creator>Fernández, Antonio</dc:creator><dc:creator>Quilez, Pablo</dc:creator><dc:creator>Verde, Maite</dc:creator><dc:creator>Galan-Malo, Patricia</dc:creator><dc:creator>Pérez, M. Dolores</dc:creator><dc:title>Is long-term serum preservation suitable for research studies? Effect of time and temperature on the measurement of anti-Leishmania antibodies in canine sera samples</dc:title><dc:identifier>ART-2025-144730</dc:identifier><dc:description>The stability of immunoglobulin G (IgG) antibodies is critical for diagnostic and research applications in veterinary medicine. This study evaluated the long-term stability of anti-Leishmania infantum IgG in canine serum samples under different storage conditions (−20 °C and −80 °C) over 2.5 years. Fifty-six serum samples were classified based on antibody concentration into low, medium, and high positive groups using an in-house enzyme-linked immunosorbent assay. Each sample was divided into aliquots and analyzed after different storage times (6 months, 1 year, 1.5, and 2.5 years). No statistically significant differences were observed in IgG concentrations across storage durations or between storage temperatures. Median antibody levels remained consistent, with minor variations attributed to assay-related variability. Correlation analyses showed strong agreement between initial and final measurements (R2 = 0.859 at −20 °C, R2 = 0.957 at −80 °C). The study underscores the suitability of −20 °C and −80 °C storage for preserving anti-Leishmania antibodies, providing valuable insights for serological diagnostics and research in veterinary science. Proper sample handling and aliquoting are recommended to maintain antibody integrity in routine diagnostics and long-term studies.</dc:description><dc:date>2025</dc:date><dc:source>http://zaguan.unizar.es/record/162105</dc:source><dc:doi>10.1080/01652176.2025.2532396</dc:doi><dc:identifier>http://zaguan.unizar.es/record/162105</dc:identifier><dc:identifier>oai:zaguan.unizar.es:162105</dc:identifier><dc:relation>info:eu-repo/grantAgreement/ES/DGA/AR15-23R</dc:relation><dc:identifier.citation>VETERINARY QUARTERLY 45, 1 (2025), 11-20</dc:identifier.citation><dc:rights>by</dc:rights><dc:rights>https://creativecommons.org/licenses/by/4.0/deed.es</dc:rights><dc:rights>info:eu-repo/semantics/openAccess</dc:rights></dc:dc>

</collection>