The local damage and systemic inflammation induced by a biodegradable polydioxanone Stent implanted in the rabbit trachea decreases markedly with Stent degradation
Resumen: Biodegradable tracheal stents have been developed to overcome the limitations of metallic and removable stents in benign airway disease. This study evaluated the local and systemic inflammatory response induced by a biodegradable polydioxanone tracheal stent in a rabbit model. Twenty-one rabbits were assigned to three follow-up groups (30, 60, and 90 days). In each group, six animals received a tracheal stent, and one served as a sham control. Clinical status and respiratory symptoms were monitored, and serial peripheral blood interleukin-8 (IL-8) levels were measured. At the end of follow-up, tracheoscopy, IL-8 quantification in tracheal lavage, and necropsy were performed. No deaths or severe respiratory symptoms occurred. Tracheoscopic findings were significantly less severe after stent degradation, with reduced congestion (p = 0.030), inflammation (p = 0.003), and secretions (p = 0.030). Two granulomas and two cases of stenosis were identified. Mean IL-8 expression in tracheal lavage (relative quantification, RQ) was 14,129 ± 3007 when the stent was present and 426 ± 100 after degradation (p = 0.003). Blood IL-8 expression increased significantly on day 1 compared with baseline (p = 0.022) and subsequently decreased (p = 0.034). Inflammatory and structural alterations induced by a polydioxanone tracheal stent decrease after stent degradation.
Idioma: Inglés
DOI: 10.3390/ijms27031309
Año: 2026
Publicado en: International Journal of Molecular Sciences 27, 3 (2026), 1309 [12 pp.]
ISSN: 1661-6596

Financiación: info:eu-repo/grantAgreement/ES/DGA/B36-23R
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Radiol. y Medicina Física (Dpto. Microb.Ped.Radio.Sal.Pú.)
Área (Departamento): Área Medicina y Cirugía Animal (Dpto. Patología Animal)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2026-03-26-14:31:06)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Radiología y Medicina Física
Artículos > Artículos por área > Medicina y Cirugía Animal



 Registro creado el 2026-03-26, última modificación el 2026-04-07


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)