000057925 001__ 57925
000057925 005__ 20210121114533.0
000057925 0247_ $$2doi$$a10.1186/s12886-015-0012-4
000057925 0248_ $$2sideral$$a89577
000057925 037__ $$aART-2015-89577
000057925 041__ $$aeng
000057925 100__ $$aCarballo-Alvarez, J.
000057925 245__ $$aVisual outcomes after bilateral trifocal diffractive intraocular lens implantation Cataract and refractive surgery
000057925 260__ $$c2015
000057925 5060_ $$aAccess copy available to the general public$$fUnrestricted
000057925 5203_ $$aBackground: In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL).
Methods: Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4?±?5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program.
Results: Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41?±?0.30 µm, coma: 0.32?±?0.22 µm and spherical aberration: 0.21?±?0.20 µm. Binocular logMAR measurements were: CDVA -0.05?±?0.05, DCIVA 0.15?±?0.10, and DCNVA 0.06?±?0.10. Mean Pelli-Robson CS was 1.40?±?0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64?±?0.14, 1.77?±?0.18, 1.44?±?0.24 and 0.98?±?0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p?<?0.0001). A mean disturbance index of 0.28?±?0.22 was obtained.
Conclusions: Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena.
000057925 536__ $$9info:eu-repo/grantAgreement/ES/ISCIII/PI11-01027$$9info:eu-repo/grantAgreement/ES/ISCIII/RD07-0062
000057925 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000057925 590__ $$a1.238$$b2015
000057925 591__ $$aOPHTHALMOLOGY$$b41 / 56 = 0.732$$c2015$$dQ3$$eT3
000057925 592__ $$a0.889$$b2015
000057925 593__ $$aMedicine (miscellaneous)$$c2015$$dQ1
000057925 593__ $$aOphthalmology$$c2015$$dQ2
000057925 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000057925 700__ $$aVazquez-Molini, J.
000057925 700__ $$aSanz-Fernandez, J.
000057925 700__ $$aGarcia-Bella, J.
000057925 700__ $$0(orcid)0000-0002-1402-3129$$aPolo, V.$$uUniversidad de Zaragoza
000057925 700__ $$aGarcía-Feijoo, J.
000057925 700__ $$aMartinez-De-La-Casa, J.M.
000057925 7102_ $$11004$$2646$$aUniversidad de Zaragoza$$bDpto. Cirugía,Ginecol.Obstetr.$$cÁrea Oftalmología
000057925 773__ $$g15, 26 (2015), [6 pp]$$pBMC OPHTHALMOLOGY$$tBMC OPHTHALMOLOGY$$x1471-2415
000057925 8564_ $$s553382$$uhttps://zaguan.unizar.es/record/57925/files/texto_completo.pdf$$yVersión publicada
000057925 8564_ $$s104899$$uhttps://zaguan.unizar.es/record/57925/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000057925 909CO $$ooai:zaguan.unizar.es:57925$$particulos$$pdriver
000057925 951__ $$a2021-01-21-11:11:45
000057925 980__ $$aARTICLE