000070928 001__ 70928
000070928 005__ 20191127155455.0
000070928 0247_ $$2doi$$a10.3390/s18051405
000070928 0248_ $$2sideral$$a106471
000070928 037__ $$aART-2018-106471
000070928 041__ $$aeng
000070928 100__ $$0(orcid)0000-0002-8617-5703$$aPérez-Bailón, J.$$uUniversidad de Zaragoza
000070928 245__ $$aA 0.18 µm CMOS LDO regulator for an on-chip sensor array impedance measurement system
000070928 260__ $$c2018
000070928 5060_ $$aAccess copy available to the general public$$fUnrestricted
000070928 5203_ $$aThis paper presents a fully integrated 0.18 µm CMOS Low-Dropout (LDO) Voltage Regulator specifically designed to meet the stringent requirements of a battery-operated impedance spectrometry multichannel CMOS micro-instrument. The proposed LDO provides a regulated 1.8 V voltage from a 3.6 V to 1.94 V battery voltage over a -40 °C to 100 °C temperature range, with a compact topology (<0.10 mm2 area) and a constant quiescent current of only 7.45 µA with 99.985% current efficiency, achieving remarkable state-of-art Figures of Merit (FoMs) for the regulating-transient performance. Experimental measurements validate its suitability for the target application, paving the way towards the future achievement of a truly portable System on Chip (SoC) platform for impedance sensors.
000070928 536__ $$9info:eu-repo/grantAgreement/ES/MINECO-FEDER/TEC2015-65750-R$$9info:eu-repo/grantAgreement/ES/UZ/JIUZ-2016-TEC-06
000070928 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000070928 590__ $$a3.031$$b2018
000070928 591__ $$aINSTRUMENTS & INSTRUMENTATION$$b15 / 61 = 0.246$$c2018$$dQ1$$eT1
000070928 591__ $$aCHEMISTRY, ANALYTICAL$$b23 / 84 = 0.274$$c2018$$dQ2$$eT1
000070928 591__ $$aELECTROCHEMISTRY$$b12 / 26 = 0.462$$c2018$$dQ2$$eT2
000070928 592__ $$a0.592$$b2018
000070928 593__ $$aAnalytical Chemistry$$c2018$$dQ2
000070928 593__ $$aAtomic and Molecular Physics, and Optics$$c2018$$dQ2
000070928 593__ $$aMedicine (miscellaneous)$$c2018$$dQ2
000070928 593__ $$aElectrical and Electronic Engineering$$c2018$$dQ2
000070928 593__ $$aInstrumentation$$c2018$$dQ2
000070928 593__ $$aBiochemistry$$c2018$$dQ2
000070928 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000070928 700__ $$0(orcid)0000-0002-4949-1539$$aMárquez, A.$$uUniversidad de Zaragoza
000070928 700__ $$0(orcid)0000-0003-2361-1077$$aCalvo, B.$$uUniversidad de Zaragoza
000070928 700__ $$0(orcid)0000-0002-5380-3013$$aMedrano, N.$$uUniversidad de Zaragoza
000070928 7102_ $$15008$$2250$$aUniversidad de Zaragoza$$bDpto. Ingeniería Electrón.Com.$$cÁrea Electrónica
000070928 773__ $$g18, 5 (2018), 1405 [17 pp]$$pSensors$$tSensors (Switzerland)$$x1424-8220
000070928 8564_ $$s1094455$$uhttps://zaguan.unizar.es/record/70928/files/texto_completo.pdf$$yVersión publicada
000070928 8564_ $$s109837$$uhttps://zaguan.unizar.es/record/70928/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000070928 909CO $$ooai:zaguan.unizar.es:70928$$particulos$$pdriver
000070928 951__ $$a2019-11-27-15:46:48
000070928 980__ $$aARTICLE