Fluid–structure simulation of a general non-contact tonometry. A required complexity?
Resumen: Understanding corneal biomechanics is important for applications regarding refractive surgery prediction outcomes and the study of pathologies affecting the cornea itself. In this regard, non-contact tonometry (NCT) is gaining interest as a non-invasive diagnostic tool in ophthalmology, and is becoming an alternative method to characterize corneal biomechanics in vivo. In general, identification of material parameters of the cornea from a NCT test relies on the inverse finite element method, for which an accurate and reliable modelization of the test is required. This study explores four different modeling strategies ranging from pure structural analysis up to a fluid–structure interaction model considering the air–cornea and humor–cornea interactions. The four approaches have been compared using clinical biomarkers commonly used in ophthalmology. Results from the simulations indicate the importance of considering the humors as fluids and the deformation of the cornea when determining the pressure applied by the air-jet during the test. Ignoring this two elements in the modeling lead to an overestimation of corneal displacement and therefore an overestimation of corneal stiffness when using the inverse finite element method.
Idioma: Inglés
DOI: 10.1016/j.cma.2018.05.031
Año: 2018
Publicado en: COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING 340 (2018), 202-215
ISSN: 0045-7825

Factor impacto JCR: 4.821 (2018)
Categ. JCR: MECHANICS rank: 6 / 134 = 0.045 (2018) - Q1 - T1
Categ. JCR: MATHEMATICS, INTERDISCIPLINARY APPLICATIONS rank: 2 / 105 = 0.019 (2018) - Q1 - T1
Categ. JCR: ENGINEERING, MULTIDISCIPLINARY rank: 6 / 88 = 0.068 (2018) - Q1 - T1

Factor impacto SCIMAGO: 2.996 - Computational Mechanics (Q1) - Computer Science Applications (Q1) - Physics and Astronomy (miscellaneous) (Q1) - Mechanics of Materials (Q1) - Mechanical Engineering (Q1)

Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2014-54981-R
Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2017-84047-R
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2020-01-17-22:11:12)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2019-06-07, última modificación el 2020-01-17


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)