000085457 001__ 85457
000085457 005__ 20201122125253.0
000085457 0247_ $$2doi$$a10.3390/s19163478
000085457 0248_ $$2sideral$$a113541
000085457 037__ $$aART-2019-113541
000085457 041__ $$aeng
000085457 100__ $$aFuertes Muñoz, Gabriel
000085457 245__ $$aA RGBD-Based interactive system for gaming-driven rehabilitation of upper limbs
000085457 260__ $$c2019
000085457 5060_ $$aAccess copy available to the general public$$fUnrestricted
000085457 5203_ $$aCurrent physiotherapy services may not be effective or suitable for certain patients due to lack of motivation, poor adherence to exercises, insufficient supervision and feedback or, in the worst case, refusal to continue with the rehabilitation plan. This paper introduces a novel approach for rehabilitation of upper limbs through KineActiv, a platform based on Microsoft Kinect v2 and developed in Unity Engine. KineActiv proposes exergames to encourage patients to perform rehabilitation exercises prescribed by a specialist, controls the patient's performance, and corrects execution errors on the fly. KineActiv comprises a web platform where the physiotherapist can review session results, monitor patient health, and adjust rehabilitation routines. We recruited 10 patients for assessing the system usability as well as the system performance. Results show that KineActiv is a usable, enjoyable and reliable system, that does not cause any negative feelings.
000085457 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000085457 590__ $$a3.275$$b2019
000085457 591__ $$aCHEMISTRY, ANALYTICAL$$b22 / 86 = 0.256$$c2019$$dQ2$$eT1
000085457 591__ $$aINSTRUMENTS & INSTRUMENTATION$$b15 / 64 = 0.234$$c2019$$dQ1$$eT1
000085457 591__ $$aENGINEERING, ELECTRICAL & ELECTRONIC$$b77 / 266 = 0.289$$c2019$$dQ2$$eT1
000085457 592__ $$a0.653$$b2019
000085457 593__ $$aInstrumentation$$c2019$$dQ1
000085457 593__ $$aAtomic and Molecular Physics, and Optics$$c2019$$dQ2
000085457 593__ $$aMedicine (miscellaneous)$$c2019$$dQ2
000085457 593__ $$aInformation Systems$$c2019$$dQ2
000085457 593__ $$aAnalytical Chemistry$$c2019$$dQ2
000085457 593__ $$aElectrical and Electronic Engineering$$c2019$$dQ2
000085457 593__ $$aBiochemistry$$c2019$$dQ3
000085457 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000085457 700__ $$aMollineda, Ramón A.
000085457 700__ $$0(orcid)0000-0001-9895-0837$$aGallardo Casero, Jesús$$uUniversidad de Zaragoza
000085457 700__ $$aPla, Filiberto
000085457 7102_ $$15007$$2570$$aUniversidad de Zaragoza$$bDpto. Informát.Ingenie.Sistms.$$cÁrea Lenguajes y Sistemas Inf.
000085457 773__ $$g19, 16 (2019), 3478 [16 pp]$$pSensors$$tSensors (Switzerland)$$x1424-8220
000085457 8564_ $$s593235$$uhttps://zaguan.unizar.es/record/85457/files/texto_completo.pdf$$yVersión publicada
000085457 8564_ $$s471842$$uhttps://zaguan.unizar.es/record/85457/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000085457 909CO $$ooai:zaguan.unizar.es:85457$$particulos$$pdriver
000085457 951__ $$a2020-11-22-12:44:25
000085457 980__ $$aARTICLE