Functional Evaluation of the Visual Pathway in Patients with Multiple Sclerosis Using a Multifunction Stimulator Monitor
Resumen: Objectives. To assess the capability of the vision monitor unit Monpack One of detecting visual function alterations in patients with multiple sclerosis (MS) and to evaluate the correlation between structural retinal parameters and functional measurements obtained with this device. Methods. Forty-eight patients with MS and 46 healthy controls were included in a cross-sectional study. All participants underwent a complete functional evaluation of the visual pathway, which included low-contrast visual acuity (LCVA), contrast sensitivity vision (CSV), automated perimetry, multifocal visual evoked potentials (mfVEPs), and pattern electroretinogram (ERG). All tests were performed using the vision monitor unit Monpack One (Metrovision, France), a multifunction stimulator device. Retinal structural measurements were obtained in all subjects using Triton swept source optical coherence tomography (Topcon, Japan). Results. Patients with MS presented reduced low-contrast VA (p<0.001) and reduced CSV at medium (p=0.001, p=0.013) and low (p=0.001, p=0.002) spatial frequencies. All visual field parameters were found to be altered in MS patients compared with controls (<= 0.001). Patients with MS presented lower amplitude of the P100 waveform of the mfVEP in areas corresponding to central (p<0.001), inferonasal (p=0.001), and inferotemporal (p=0.003) retina. The pattern ERG did not show significant differences. Significant correlations were observed between structural retinal measurements and functional parameters, especially between the inner macular areas and measurements corresponding to contrast sensitivity and perimetry indexes. Conclusions. Patients with MS present visual dysfunction detectable with the vision monitor unit Monpack One. This device may be a fast and useful tool to provide a full evaluation of axonal damage in patients with multiple sclerosis.
Idioma: Inglés
DOI: 10.1155/2019/2890193
Año: 2019
Publicado en: Journal of Ophthalmology 2019 (2019), 2890193 1-8
ISSN: 2090-004X

Factor impacto JCR: 1.447 (2019)
Categ. JCR: OPHTHALMOLOGY rank: 41 / 60 = 0.683 (2019) - Q3 - T3
Categ. JCR: MEDICINE, RESEARCH & EXPERIMENTAL rank: 116 / 138 = 0.841 (2019) - Q4 - T3

Factor impacto SCIMAGO: 0.828 - Ophthalmology (Q2)

Financiación: info:eu-repo/grantAgreement/ES/ISCIII/CM14-00026
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Oftalmología (Dpto. Cirugía,Ginecol.Obstetr.)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2020-07-16-09:49:09)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2019-12-12, última modificación el 2020-07-16


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)