000087814 001__ 87814
000087814 005__ 20200218165903.0
000087814 0247_ $$2doi$$a10.2495/HT160161
000087814 0248_ $$2sideral$$a116041
000087814 037__ $$aART-2016-116041
000087814 041__ $$aeng
000087814 100__ $$aEcharri Iribarren, Víctor
000087814 245__ $$aEnergy efficiency of flooded roofs. The University of Alicante Museum
000087814 260__ $$c2016
000087814 5060_ $$aAccess copy available to the general public$$fUnrestricted
000087814 5203_ $$aInverted flat roofs were adopted as a common construction solution throughout the Modern Movement. They require greater protection of the waterproofing layer and sufficient thermal insulation. Depending on the climate conditions, a thicker or thinner thermal layer is installed and energy saving in keeping with the climatic conditions, regulations or national or regional energy policies is obtained. However, the common construction systems tend to be focused on minimising the construction costs of each project, using thermal insulation layers of extruded polystyrene, a modified bitumen waterproofing layer and a finishing layer of 5 cm of gravel. In the case of trafficable roofs, this layer is substituted with ceramic or hydraulic concrete paving. These solutions have given rise to an enormous reduction in the thermal mass of the roof layers located above the isolation layer and consequently, a lack of thermal inertia with which to cushion the effect of the thermal wave of the outdoor environment produced in the indoor climate of the building. Roofs flooded with water in climatologies which allow their application generate significant thermal inertia depending on the depth of the water. They reduce the amplitude of the thermal wave produced in the inside temperature of the buildings by the external thermal variations, generating a considerable increase in comfort and a reduction in energy consumption. This paper outlines the research carried out in the Alicante University Museum. The whole building and its flooded roof have been monitored over a full year cycle and data has been obtained regarding the dry interior temperatures of each layer of the walls, outdoor temperatures and solar radiation, relative humidities, etc. Through the use of simulation tools, comparative results of this roof with respect to inverted flat roofs have been obtained, such as the decrement factor and the heat wave.
000087814 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000087814 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000087814 700__ $$0(orcid)0000-0002-3937-454X$$aEspinosa-Fernández, Almudena$$uUniversidad de Zaragoza
000087814 700__ $$aGaliano Garrigós, Antonio Luis
000087814 7102_ $$15010$$2110$$aUniversidad de Zaragoza$$bUnidad Predepartam. Arquitect.$$cArea Construc. Arquitectónicas
000087814 773__ $$g106 (2016), 163-175$$pWIT trans. eng. sci.$$tWIT transactions on engineering sciences$$x1746-4471
000087814 8564_ $$s1277813$$uhttps://zaguan.unizar.es/record/87814/files/texto_completo.pdf$$yVersión publicada
000087814 8564_ $$s309599$$uhttps://zaguan.unizar.es/record/87814/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000087814 909CO $$ooai:zaguan.unizar.es:87814$$particulos$$pdriver
000087814 951__ $$a2020-02-18-15:38:28
000087814 980__ $$aARTICLE