Initial performance of the CUORE detector

Cushman, J.S. ; Alduino, C. ; Alfonso, K. ; Avignone, F.T. ; Azzolini, O. ; Bari, G. ; Bellini, F. ; Benato, G. ; Bersani, A. ; Biassoni, M. ; Branca, A. ; Brofferio, C. ; Bucci, C. ; Camacho, A. ; Caminata, A. ; Canonica, L. ; Cao, X.G. ; Capelli, S. ; Cappelli, L. ; Cardani, L. ; Carniti, P. ; Casali, N. ; Cassina, L. ; Chiesa, D. ; Chott, N. ; Clemenza, M. ; Copello, S. ; Cosmelli, C. ; Cremonesi, O. ; Creswick, R.J. ; D''Addabbo, A. ; D''Aguanno, D. ; Dafinei, I. ; Davis, C.J. ; Dell''Oro, S. ; Deninno, M.M. ; Domizio, S.D. ; Vacri, M.L.D. ; Drobizhev, A. ; Fang, D.Q. ; Faverzani, M. ; Ferri, E. ; Ferroni, F. ; Fiorini, E. ; Franceschi, M.A. ; Freedman, S.J. ; Fujikawa, B.K. ; Giachero, A. ; Gironi, L. ; Giuliani, A. ; Gladstone, L. ; Gorla, P. ; Gotti, C. ; Gutierrez, T.D. ; Han, K. ; Heeger, K.M. ; Hennings-Yeomans, R. ; Huang, H.Z. ; Keppel, G. ; Kolomensky, Y.G. ; Leder, A. ; Ligi, C. ; Lim, K.E. ; Ma, Y.G. ; Marini, L. ; Martinez, M. (Universidad de Zaragoza) ; Maruyama, R.H. ; Mei, Y. ; Moggi, N. ; Morganti, S. ; Nagorny, S.S. ; Napolitano, T. ; Nastasi, M. ; Nones, C. ; Norman, E.B. ; Novati, V. ; Nucciotti, A. ; Nutini, I. ; O''Donnell, T. ; Ouellet, J.L. ; Pagliarone, C.E. ; Pallavicini, M. ; Palmieri, V. ; Pattavina, L. ; Pavan, M. ; Pessina, G. ; Pira, C. ; Pirro, S. ; Pozzi, S. ; Previtali, E. ; Reindl, F. ; Rosenfeld, C. ; Rusconi, C. ; Sakai, M. ; Sangiorgio, S. ; Santone, D. ; Schmidt, B. ; Schmidt, J. ; Scielzo, N.D. ; Singh, V. ; Sisti, M. ; Taffarello, L. ; Terranova, F. ; Tomei, C. ; Vignati, M. ; Wagaarachchi, S.L. ; Wang, B.S. ; Wang, H.W. ; Welliver, B. ; Wilson, J. ; Wilson, K. ; Winslow, L.A. ; Wise, T. ; Zanotti, L. ; Zhang, G.Q. ; Zimmermann, S. ; Zucchelli, S.
Initial performance of the CUORE detector
Resumen: CUORE, the Cryogenic Underground Observatory for Rare Events, is an experiment searching for the neutrinoless double-beta decay of 130Te. The first CUORE dataset was acquired in May and June 2017 and consisted of 10.6 kg-yr of TeO2 exposure, with several days of calibration data before and after the physics dataset. We discuss here the initial performance of the CUORE detector and cryostat in this first dataset.
Idioma: Inglés
DOI: 10.1088/1742-6596/1342/1/012114
Año: 2020
Publicado en: Journal of Physics: Conference Series 1342 (2020), 012114 1-5
ISSN: 1742-6588

Factor impacto SCIMAGO: 0.21 - Physics and Astronomy (miscellaneous) (Q4)

Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Física Atóm.Molec.y Nucl. (Dpto. Física Teórica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2022-04-25-10:37:09)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Física Atómica, Molecular y Nuclear



 Registro creado el 2020-05-08, última modificación el 2022-04-25