Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor
Resumen: Purpose To analyse nocturnal intraocular pressure (IOP) fluctuations in patients with obstructive sleep apnea syndrome (OSAS) using a contact lens sensor (CLS) and to identify associations between the OSAS parameters determined by polysomnographic study (PSG) and IOP changes. Method Prospective, observational study. Twenty participants suspected of having OSAS were recruited. During PSG study, IOP was monitored using a CLS placed in the eye of the patient. The patients were classified according to the apnea-hypopnea index (AHI) in two categories, severe (>30) or mild/moderate (<30) OSAS. We evaluated several parameters determined by the IOP curves, including nocturnal elevations (acrophase) and plateau times in acrophase (PTs) defined by mathematical and visual methods. Results The IOP curves exhibited a nocturnal acrophase followed by PTs of varying extents at which the IOP remained higher than daytime measurement with small variations. We found significant differences in the length of the PTs in patients with severe OSAS compared to those with mild/moderate disease (P = 0.032/P = 0.028). We found a positive correlation between PTs and OSAS severity measured by the total number of apneic events (r = 0.681/ 0.751 P = 0.004/0.001) and AHI (r = 0.674/0.710, P = 0.004/0.002). Respiratory-related arousal and oxygen saturation also were associated significantly with the IOP PT length. Conclusions Periods of nocturnal IOP elevation lasted longer in severe OSAS patients than those with mild/moderate OSAS and correlate with the severity of the disease. The length of the nocturnal PT is also associated to respiratory parameters altered in patients with OSAS.
Idioma: Inglés
DOI: 10.1371/journal.pone.0229856
Año: 2020
Publicado en: PloS one 15, 3 (2020), e0229856 [18 pp.]
ISSN: 1932-6203

Factor impacto JCR: 3.24 (2020)
Categ. JCR: MULTIDISCIPLINARY SCIENCES rank: 26 / 73 = 0.356 (2020) - Q2 - T2
Factor impacto SCIMAGO: 0.99 - Multidisciplinary (Q1)

Financiación: info:eu-repo/grantAgreement/ES/ISCIII/RD07-0063
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Oftalmología (Dpto. Cirugía)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2021-09-02-09:01:49)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Oftalmología



 Registro creado el 2020-06-09, última modificación el 2021-09-02


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)