A numerical approach to analyze the performance of a PEF-Ohmic heating system in microbial inactivation of solid food

Moya, Jara (Universidad de Zaragoza) ; Astráin Redín, L. (Universidad de Zaragoza) ; Grasa Orús, J. (Universidad de Zaragoza) ; Cebrián, G. (Universidad de Zaragoza) ; Calvo Calzada, Begoña (Universidad de Zaragoza) ; Álvarez, I. (Universidad de Zaragoza)
A numerical approach to analyze the performance of a PEF-Ohmic heating system in microbial inactivation of solid food
Resumen: Pulsed Electric Fields (PEF) technology has been recently proposed as a new ohmic-heating system for the heat treatment of solid products in short periods (less than 1 min). However, similar to traditional ohmic heating, non-homogeneous distribution of temperature has been observed and cold points appeared in the interphase between the solid treated product and the electrodes, which can limit the technology for assuring food safety for treated solid products. In this investigation, a computational axisymmetric model of a lab-scale PEF system for a solid product (agar cylinder) was developed. This model was used to predict the temperature and the electric field distribution, treatment time, and the microbial inactivation (Salmonella Typhimurium 878) in the solid product after a PEF-ohmic treatment. Using a factorial analysis, a total of 8 process conditions with different settings of applied field strength levels (2.5–3.75 kV/cm), frequencies (100–200 Hz), and initial agar and electrode temperature (40–50°C) were simulated for the agar cylinder in order to identify the effect and optimal values of these parameters, which offer the most temperature homogeneity. The results showed that the initial temperature of the agar and the electrodes was of great importance in achieving the best temperature uniformity, limiting the occurrence of cold points, and therefore, improving the homogeneity in the level of inactivation of Salmonella Typhimurium 878 all over the agar cylinder. A treatment of 2.3 s would be enough at 3.75 kV/cm, 200 Hz with an initial temperature of 50°C of the agar and the electrodes, for a 5-Log10 reduction of Salmonella Typhimurium 878 in the whole product with a deviation of 9°C between the coldest and hottest point of the solid.
Idioma: Inglés
DOI: 10.3389/frfst.2022.880688
Año: 2022
Publicado en: Frontiers in Food Science and Technology 2 (2022), 880688 [11 pp.]
ISSN: 2674-1121

Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)
Área (Departamento): Área Tecnología de Alimentos (Dpto. Produc.Animal Cienc.Ali.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2023-08-30-10:59:37)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2022-11-24, última modificación el 2023-08-30


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)