000129498 001__ 129498
000129498 005__ 20231219145829.0
000129498 0247_ $$2doi$$a10.1109/TR.2015.2417431
000129498 0248_ $$2sideral$$a90813
000129498 037__ $$aART-2015-90813
000129498 041__ $$aeng
000129498 100__ $$aBerrade, M. D.
000129498 245__ $$aSome insights into the effect of maintenance quality for a protection system
000129498 260__ $$c2015
000129498 5060_ $$aAccess copy available to the general public$$fUnrestricted
000129498 5203_ $$aThis paper considers an inspection and preventive replacement policy for a one-component protection or cold standby system. Inspection is imperfect, and subject to false positives and negatives; preventive replacement may also be of poor quality. We determine conditions relating to the quality of the inspection and preventive replacement under which a maintained system would not benefit from the execution of inspections and preventive maintenance. We present examples with decreasing failure rate component lifetimes in which preventive replacement is cost-optimal, contrary to the classic policy. Such cases arise when inspections do not necessarily detect the failed state.
000129498 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000129498 590__ $$a2.287$$b2015
000129498 591__ $$aCOMPUTER SCIENCE, HARDWARE & ARCHITECTURE$$b6 / 51 = 0.118$$c2015$$dQ1$$eT1
000129498 591__ $$aENGINEERING, ELECTRICAL & ELECTRONIC$$b50 / 255 = 0.196$$c2015$$dQ1$$eT1
000129498 591__ $$aCOMPUTER SCIENCE, SOFTWARE ENGINEERING$$b7 / 105 = 0.067$$c2015$$dQ1$$eT1
000129498 592__ $$a1.679$$b2015
000129498 593__ $$aSafety, Risk, Reliability and Quality$$c2015$$dQ1
000129498 593__ $$aElectrical and Electronic Engineering$$c2015$$dQ1
000129498 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/acceptedVersion
000129498 700__ $$aScarf, P. A.
000129498 700__ $$aCavalcante, C. A. V.
000129498 773__ $$g64, 2 (2015), 661-672$$pIEEE trans. reliab.$$tIEEE TRANSACTIONS ON RELIABILITY$$x0018-9529
000129498 8564_ $$s2148158$$uhttps://zaguan.unizar.es/record/129498/files/texto_completo.pdf$$yPostprint
000129498 8564_ $$s2796124$$uhttps://zaguan.unizar.es/record/129498/files/texto_completo.jpg?subformat=icon$$xicon$$yPostprint
000129498 909CO $$ooai:zaguan.unizar.es:129498$$particulos$$pdriver
000129498 951__ $$a2023-12-19-14:02:21
000129498 980__ $$aARTICLE