Left Bundle Branch Area Pacing Generates More Physiological Ventricular Activation Sequences than Right Ventricular Pacing
Resumen: Left bundle branch area pacing (LBBAP) has been proposed as a novel physiological pacing modality to overcome ventricular dyssynchrony reported in bradycardic patients who undergo conventional right ventricular pacing (RVP). The standard non-invasive measure of depolarization synchrony is the QRS duration. However, a deeper understanding of not only the activation time but also the activation sequence is required to evaluate the effects of RVP and LBBAP in bradycardic patients. This study aimed to characterize and compare the ventricular activation sequences obtained from both pacing techniques, LBBAP and RVP, by analyzing the standard 12-lead ECGs of bradycardic patients with physiological conduction. 22 RVP and 42 LBBAP ECG recordings were collected before and after pacemaker implantation. High (HF) and low (LF) frequency-based methods for QRS complex analysis were used and the precordial activation sequence and activation delay (pAD) were estimated. Results showed more physiological activation sequences after LBBAP than after RVP, with lower pAD (p<0.01) after LBBAP [HF:12(2,15) vs29(6,56); LF:9(-25,13) vs31(17,38)]. The proposed ECG methodology could be used in clinical practice to map more physiological pacing targets in pacemaker implantation.
Idioma: Inglés
DOI: 10.22489/CinC.2023.316
Año: 2023
Publicado en: Computing in Cardiology (2023), [4 pp.]
ISSN: 2325-8861

Factor impacto CITESCORE: 1.1 - Computer Science (all) (Q4) - Cardiology and Cardiovascular Medicine (Q4)

Factor impacto SCIMAGO: 0.227 - Computer Science (miscellaneous) - Cardiology and Cardiovascular Medicine

Tipo y forma: Comunicación congreso (Versión definitiva)
Área (Departamento): Area Medicina (Dpto. Medicina, Psiqu. y Derm.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2024-09-12-13:15:39)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Teoría de la Señal y Comunicaciones
Artículos > Artículos por área > Medicina



 Registro creado el 2024-01-11, última modificación el 2024-09-12


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)