Structure optimization and exergy analysis of a two-stage TEC with two different connections
Resumen: This paper develops three dimensional numerical models of a two-stage series-connected TEC model and a two-stage parallel-connected TEC model. NSGA-II is used to optimize their electric current, height of lower stage and ratio of channel width and thickness of fin in the case of constant thermoelectric material volume. Two objectives, exergy efficiency and irreversibility are considered simultaneously. The optimal values one Pareto front are obtained by three decision making methods, Shannon''s entropy, TOPSIS and LINMAP, while deviation index is a criterion for evaluating three decision making methods. Sensitive analysis has been carried out to investigate the influence of three variables to be optimized. And TEC with and without plate-fin heat exchanger have been compared. The results show that solution selected by LINMAP is the most compromising solution. The parallel connected TEC saves about 50% of the power consumption compared to the series connected TEC under the same temperature difference. Optimal variables are discussed to obtain the most energy efficient solution with optimal configuration and plate-fin heat exchanger.
Idioma: Inglés
DOI: 10.1016/j.energy.2019.05.077
Año: 2019
Publicado en: Energy 180 (2019), 175-191
ISSN: 0360-5442

Factor impacto JCR: 6.082 (2019)
Categ. JCR: THERMODYNAMICS rank: 3 / 61 = 0.049 (2019) - Q1 - T1
Categ. JCR: ENERGY & FUELS rank: 20 / 112 = 0.179 (2019) - Q1 - T1

Factor impacto SCIMAGO: 2.166 - Electrical and Electronic Engineering (Q1) - Energy (miscellaneous) (Q1) - Energy Engineering and Power Technology (Q1) - Management, Monitoring, Policy and Law (Q1) - Civil and Structural Engineering (Q1) - Fuel Technology (Q1) - Industrial and Manufacturing Engineering (Q1) - Building and Construction (Q1)

Financiación: info:eu-repo/grantAgreement/ES/UZ/JIUZ-2017-TEC-10
Tipo y forma: Article (PostPrint)
Área (Departamento): Área Máquinas y Motores Térmi. (Dpto. Ingeniería Mecánica)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes. If you remix, transform, or build upon the material, you may not distribute the modified material.


Exportado de SIDERAL (2024-01-31-19:18:17)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles



 Record created 2024-01-31, last modified 2024-01-31


Postprint: