Characterizing atherosclerotic tissues: in silico analysis of mechanical properties using intravascular ultrasound and inverse finite element methods
Resumen: Atherosclerosis is a prevalent cause of acute coronary syndromes that consists of lipid deposition inside the artery wall, creating an atherosclerotic plaque. Early detection may prevent the risk of plaque rupture. Nowadays, intravascular ultrasound (IVUS) is the most common medical imaging technology for atherosclerotic plaque detection. It provides an image of the section of the coronary wall and, in combination with new techniques, can estimate the displacement or strain fields. From these magnitudes and by inverse analysis, it is possible to estimate the mechanical properties of the plaque tissues and their stress distribution. In this paper, we presented a methodology based on two approaches to characterize the mechanical properties of atherosclerotic tissues. The first approach estimated the linear behavior under particular pressure. In contrast, the second technique yielded the non-linear hyperelastic material curves for the fibrotic tissues across the complete physiological pressure range. To establish and validate this method, the theoretical framework employed in silico models to simulate atherosclerotic plaques and their IVUS data. We analyzed different materials and real geometries with finite element (FE) models. After the segmentation of the fibrotic, calcification, and lipid tissues, an inverse FE analysis was performed to estimate the mechanical response of the tissues. Both approaches employed an optimization process to obtain the mechanical properties by minimizing the error between the radial strains obtained from the simulated IVUS and those achieved in each iteration. The second methodology was successfully applied to five distinct real geometries and four different fibrotic tissues, getting median R2 of 0.97 and 0.92, respectively, when comparing the real and estimated behavior curves. In addition, the last technique reduced errors in the estimated plaque strain field by more than 20% during the optimization process, compared to the former approach. The findings enabled the estimation of the stress field over the hyperelastic plaque tissues, providing valuable insights into its risk of rupture.
Idioma: Alemán
DOI: 10.3389/fbioe.2023.1304278
Año: 2023
Publicado en: Frontiers in Bioengineering and Biotechnology 11 (2023), 1-15
ISSN: 2296-4185

Factor impacto JCR: 4.3 (2023)
Categ. JCR: BIOTECHNOLOGY & APPLIED MICROBIOLOGY rank: 41 / 174 = 0.236 (2023) - Q1 - T1
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 39 / 123 = 0.317 (2023) - Q2 - T1

Factor impacto CITESCORE: 8.3 - Biotechnology (Q1) - Histology (Q1) - Biomedical Engineering (Q1) - Bioengineering (Q1)

Factor impacto SCIMAGO: 0.893 - Biomedical Engineering (Q1) - Histology (Q2) - Biotechnology (Q2) - Bioengineering (Q2)

Financiación: info:eu-repo/grantAgreement/ES/DGA-CUS/581-2020
Financiación: info:eu-repo/grantAgreement/ES/DGA-FSE/T24-20R
Financiación: info:eu-repo/grantAgreement/ES/MICINN/PID2019-107517RB-I00
Financiación: info:eu-repo/grantAgreement/ES/MICINN/PID2022-140219OB-I00
Tipo y forma: Article (Published version)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.


Exportado de SIDERAL (2024-11-22-12:10:44)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles > Artículos por área > Mec. de Medios Contínuos y Teor. de Estructuras



 Record created 2024-02-19, last modified 2024-11-25


Versión publicada:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)