Global analysis of building façade exposure to water penetration in Chile
Resumen: In this study, the exposure of building façades in Chile to wind-driven rain and driving rain wind pressure was analysed. Daily climatic data from 29 weather stations throughout Chile were used to determine these exposures in scalar terms and are presented in exposure maps. These values were used to estimate the risk index for water penetration at each location and to determine the relationships between the different exposure indices calculated from the daily, monthly, and annual data. Finally, the directional characterisations of these exposures were determined with an alternative method that was based on climatic data from the Chilean stations. This method was used to quantify the exposure of façades oriented in any direction in 6 cities that represent the country's climate: Santiago, Concepción, La Serena, Temuco, Antofagasta, and Puerto Montt. In general, the exposure of façades to water penetration progressively increases from north to south. However, this pattern is affected by the topography of each location, especially in the capital and southern regions. Valdivia, which is located in the centre, and Balmaceda, which is located in the south, showed the greatest risk of water penetration in Chilean façades.
Idioma: Inglés
DOI: 10.1016/j.buildenv.2013.09.001
Año: 2013
Publicado en: Building and Environment 70 (2013), 284-297
ISSN: 0360-1323

Factor impacto JCR: 2.7 (2013)
Categ. JCR: CONSTRUCTION & BUILDING TECHNOLOGY rank: 5 / 58 = 0.086 (2013) - Q1 - T1
Categ. JCR: ENGINEERING, CIVIL rank: 5 / 124 = 0.04 (2013) - Q1 - T1
Categ. JCR: ENGINEERING, ENVIRONMENTAL rank: 15 / 46 = 0.326 (2013) - Q2 - T1

Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/BIA2012-31609
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Area Ingeniería Construcción (Dpto. Ingeniería Mecánica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2025-01-31-16:01:44)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Ingeniería de la Construcción



 Registro creado el 2025-01-31, última modificación el 2025-01-31


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)