3D computational parametric analysis of eccentric atheroma plaque: Influence of axial and circumferential residual stresses
Resumen: Plaque rupture plays a role in the majority of acute coronary syndromes. Rupture has usually been associated with stress concentrations, which are mainly affected by the plaque geometry and the tissue properties. The aim of this study is to evaluate the influence of morphology on the risk of plaque rupture, including the main geometrical factors, and to assess the role of circumferential and axial residual stresses by means of a parametric 3D finite element model. For this purpose, a 3D parametric finite element model of the coronary artery with eccentric atheroma plaque was developed. Healthy (adventitia and media in areas without atheroma plaque) and diseased (fibrotic and lipidic) tissues were considered in the model. The geometrical parameters used to define and design the idealized coronary plaque anatomy were the lipid core length, the stenosis ratio, the fibrous cap thickness, and the lipid core ratio. Finally, residual stresses in longitudinal and circumferential directions were incorporated into the model to analyse the influence of the important mechanical factors in the vulnerability of the plaque. Viewing the results, we conclude that residual stresses should be considered in the modelling of this kind of problems since they cause a significant alteration of the vulnerable plaque region limits. The obtained results show that the fibrous cap thickness and the lipid core length, in combination with the lipid core width, appear to be the key morphological parameters that play a determinant role in the maximal principal stress (MPS). However, the stenosis ratio is found to not play a significant role in vulnerability related to the MPS. Plaque rupture should therefore be observed as a consequence, not only of the cap thickness, but as a combination of the stenosis ratio, the fibrous cap thickness and the lipid core dimensions.
Idioma: Inglés
DOI: 10.1007/s10237-011-0369-0
Año: 2012
Publicado en: BIOMECHANICS AND MODELING IN MECHANOBIOLOGY 11, 7 (2012), 1001-1013
ISSN: 1617-7959

Factor impacto JCR: 3.331 (2012)
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 11 / 76 = 0.145 (2012) - Q1 - T1
Categ. JCR: BIOPHYSICS rank: 26 / 71 = 0.366 (2012) - Q2 - T2

Financiación: info:eu-repo/grantAgreement/ES/DGA/B137-09
Financiación: info:eu-repo/grantAgreement/ES/MINECO/DPI2010-20746-C03-01
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Mec.Med.Cont. y Teor.Est. (Dpto. Ingeniería Mecánica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2025-02-03-11:02:16)