A velostat-based pressure-sensitive mat for center-of-pressure measurements: A preliminary study

Martinez-Cesteros J. (Universidad de Zaragoza) ; Medrano-Sanchez C. (Universidad de Zaragoza) ; Plaza-Garcia I. (Universidad de Zaragoza) ; Igual-Catalan R. (Universidad de Zaragoza) ; Albiol-Pérez S. (Universidad de Zaragoza)
A velostat-based pressure-sensitive mat for center-of-pressure measurements: A preliminary study
Resumen: Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.
Idioma: Inglés
DOI: 10.3390/ijerph18115958
Año: 2021
Publicado en: International journal of environmental research and public health 18, 11 (2021), 5958 [13 pp.]
ISSN: 1661-7827

Factor impacto JCR: 4.614 (2021)
Categ. JCR: PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH rank: 45 / 182 = 0.247 (2021) - Q1 - T1
Categ. JCR: ENVIRONMENTAL SCIENCES rank: 100 / 279 = 0.358 (2021) - Q2 - T2
Categ. JCR: PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH rank: 71 / 210 = 0.338 (2021) - Q2 - T2

Factor impacto CITESCORE: 4.5 - Medicine (Q2) - Environmental Science (Q2)

Factor impacto SCIMAGO: 0.814 - Pollution (Q1) - Health, Toxicology and Mutagenesis (Q1)

Financiación: info:eu-repo/grantAgreement/ES/DGA-FEDER/T49-20R
Financiación: info:eu-repo/grantAgreement/ES/ISCIII-FIS/PI17-00465
Financiación: info:eu-repo/grantAgreement/ES/MCIU/FPU18-04282
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Arquit.Tecnología Comput. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Tecnología Electrónica (Dpto. Ingeniería Electrón.Com.)
Área (Departamento): Área Ingeniería Eléctrica (Dpto. Ingeniería Eléctrica)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2025-03-10-12:56:56)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Arquitectura y Tecnología de Computadores
Artículos > Artículos por área > Tecnología Electrónica
Artículos > Artículos por área > Ingeniería Eléctrica



 Registro creado el 2025-03-10, última modificación el 2025-03-10


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)