000151693 001__ 151693
000151693 005__ 20251017144632.0
000151693 0247_ $$2doi$$a10.3390/jfb16020071
000151693 0248_ $$2sideral$$a143260
000151693 037__ $$aART-2025-143260
000151693 041__ $$aeng
000151693 100__ $$aPérez-Pevida, Esteban
000151693 245__ $$aThe Relationship Between Peri-Implant Marginal Bone Loss and Resonance Frequency Analysis
000151693 260__ $$c2025
000151693 5060_ $$aAccess copy available to the general public$$fUnrestricted
000151693 5203_ $$aResonance frequency analysis (RFA) has been used as a diagnostic method to measure implant stability at all stages of healing. In addition to evaluating the status of the peri-implant marginal bone, it can also indicate the most appropriate time to load the implant. This in vitro study aimed to evaluate the efficacy of RFA as a diagnostic method for the detection of peri-implant marginal bone loss (MBL). Forty bone-level Klockner Vega implants were placed in a polyurethane block with elastic properties similar to those of the maxillary bone. The insertion torque and primary implant stability at the time of placement were measured using an RFA device. A circumferential peri-implant defect was created by removing the cortical bone portion in each implant using a trephine. The stability values were measured again using RFA. The stability values measured using RFA were lower after the creation of the circumferential peri-implant defect, indicating a statistically significant decrease in implant stability. The results of the study tend to show a relationship between peri-implant marginal bone loss and modifications in implant stability measured by RFA.
000151693 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttps://creativecommons.org/licenses/by/4.0/deed.es
000151693 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000151693 700__ $$aMonteagudo-Villalobos, Iván
000151693 700__ $$aChávarri-Prado, David
000151693 700__ $$aEstrada-Martínez, Alejandro
000151693 700__ $$aBeltrán-Guijarro, Miguel$$uUniversidad de Zaragoza
000151693 700__ $$aDiéguez-Pereira, Markel
000151693 700__ $$aBrizuela-Velasco, Aritza
000151693 7102_ $$11013$$2275$$aUniversidad de Zaragoza$$bDpto. Cirugía$$cÁrea Estomatología
000151693 773__ $$g16, 2 (2025), 71 [13 pp.]$$pJ. funct. biomater.$$tJournal of Functional Biomaterials$$x2079-4983
000151693 8564_ $$s2463994$$uhttps://zaguan.unizar.es/record/151693/files/texto_completo.pdf$$yVersión publicada
000151693 8564_ $$s2610034$$uhttps://zaguan.unizar.es/record/151693/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000151693 909CO $$ooai:zaguan.unizar.es:151693$$particulos$$pdriver
000151693 951__ $$a2025-10-17-14:27:00
000151693 980__ $$aARTICLE