Transient and rapid QRS-widening associated with a J-wave pattern predicts impending ventricular fibrillation in experimental myocardial infarction
Resumen: Background
Certain types of the early repolarization phenomenon, previously considered to be benign, have been reported to be associated with ventricular fibrillation (VF), both in population-based studies and in the myocardial infarction (MI) settings.
Objective
To analyze whether QRS widening and appearance of a J-wave pattern in experimental MI settings is predictive of VF.
Methods
MI was induced in 32 pigs by 40-minute inflation of an angioplasty balloon in the left descending artery, and electrocardiogram was continuously recorded. Multilead QRS boundaries were computed, and QRS duration was calculated on a beat-to-beat basis during the occlusion period for each pig. An association between QRS widening and subsequent VF was studied using receiver operating characteristic curve analysis. Electrocardiograms at maximum QRS duration were reviewed for the presence of a J-wave pattern.
Results
Sixteen animals had VF episodes during the occlusion period. Two peaks of QRS widening were found in all animals: the first peak immediately on left descending artery occlusion and the second peak 19.1 ± 4.0 minutes later. The magnitude of changes in the QRS width over time had significant interindividual differences. A QRS widening of ≥28 ms during a 3-minute time window was observed in 14 animals and predicted impending VF (selectivity 80%, specificity 73%, positive predictive value 57%, and negative predictive value 89%; P = .008). In 10 of 14 (71%) pigs, a J-wave pattern appeared at maximal QRS duration. The appearance of a J-wave pattern predicted VF with selectivity 80%, specificity 68%, positive predictive value 53%, and negative predictive value 88% (P = .02).
Conclusion
Transient QRS widening, commonly associated with a J-wave pattern, appears to predict impending VF in acute ischemia settings and motivates further clinical studies for monitoring immediate risk of VF in MI.

Idioma: Inglés
DOI: 10.1016/j.hrthm.2014.03.048
Año: 2014
Publicado en: HEART RHYTHM 11, 7 (2014), 1195-1201
ISSN: 1547-5271

Factor impacto JCR: 5.076 (2014)
Categ. JCR: CARDIAC & CARDIOVASCULAR SYSTEMS rank: 18 / 123 = 0.146 (2014) - Q1 - T1
Tipo y forma: Article (PostPrint)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes. If you remix, transform, or build upon the material, you may not distribute the modified material.


Exportado de SIDERAL (2026-01-28-15:37:47)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles > Artículos por área > Teoría de la Señal y Comunicaciones



 Record created 2026-01-28, last modified 2026-01-28


Postprint:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)