Estudios
I+D+I
Institución
Internacional
Vida Universitaria
Atlantis Institut des Sciences Fictives
Recherche
Soumettre
Personnaliser
Vos alertes
Vos paniers
Vos recherches
Aide
EN
/
ES
Accueil
>
articulos
> Mo/Au transition-edge sensors: Effect of sensor size and absorber stem position on parameters and noise
Statistiques d'utilisation
Graphiques
Mo/Au transition-edge sensors: Effect of sensor size and absorber stem position on parameters and noise
Fàbrega, Lourdes
;
Camón, Agustín
;
Pobes, Carlos
;
Strichovanec, Pavel
;
Bolea, J.
Resumen:
The basic transition parameters and excess noise of Mo/Au-based transition-edge sensor (TES) x-ray detectors without banks and with Au absorber are analyzed as a function of TES dimensions and absorber stems position. We show the effect of the absorber stems and TES dimensions on these parameters. We observe that the logarithmic derivatives of R(T) are reduced and develop non-monotonous behavior vs bias as stems are placed on the Mo/Au sensor area, progressively disturbing the current flow inside the TES. TESs with outer tangent stems display higher excess noise but also higher figures of merit because of their higher α and β values. We find that both longer and narrower TESs have higher excess noise so that a trade-off is required for TES performance optimization. We discuss some hints for that. The possible origins of the experimental excess noise of these devices are also explored and discussed.
Idioma:
Inglés
DOI:
10.1063/5.0303520
Año:
2026
Publicado en:
Journal of Applied Physics
139 (2026), 034502 [10 pp.]
ISSN:
0021-8979
Financiación:
info:eu-repo/grantAgreement/ES/AEI/CEX2023-001263-S
Financiación:
info:eu-repo/grantAgreement/ES/DGA/E09-23R-QMAD
Financiación:
info:eu-repo/grantAgreement/ES/MICINN/CEX2023-001286-S
Financiación:
info:eu-repo/grantAgreement/ES/MICINN/PID2021-122955OB-C42
Financiación:
info:eu-repo/grantAgreement/ES/MICINN/2021-SGR-00445
Tipo y forma:
Article (Published version)
Dataset asociado:
optical microscope images of TESs, graphs of Z(¿) with fits, error bars on parameters extracted from Z(¿) fits, and a representative graph of noise and its contributions.
( https://aip.figshare.com/collections/Mo_Au_Transition-Edge_Sensors_effect_of_sensor_size_and_absorber_stem_position_on_parameters_and_noise_/8218766)
Exportado de SIDERAL (2026-02-04-13:15:02)
Permalink:
Copy
Visitas y descargas
Este artículo se encuentra en las siguientes colecciones:
articulos
Retour à la recherche
Notice créée le 2026-02-04, modifiée le 2026-02-04
Versión publicada:
PDF
Évaluer ce document:
Rate this document:
1
2
3
4
5
(Pas encore évalué)
Ajouter au panier personnel
Exporter vers
BibTeX
,
MARC
,
MARCXML
,
DC
,
EndNote
,
NLM
,
RefWorks