Cryogenic light detectors with thermal signal amplification for 0νββ search experiments

Armatol, A. ; Barabash, A.S. ; Baudin, D. ; Berest, V. ; Beretta, M. ; Bergé, L. ; Buchynska, M. ; Calvo-Mozota, J.M. ; Capelli, C. ; Carniti, P. ; Chapellier, M. ; Dafinei, I. ; Danevich, F.A. ; Dixon, T. ; Drobizhev, A. ; Dumoulin, L. ; Ferri, F. ; Gallas, A. ; Giuliani, A. ; Gotti, C. ; Gras, Ph. ; Ianni, A. ; Imbert, L. ; Khalife, H. ; Kobychev, V.V. ; Konovalov, S.I. ; Loaiza, P. ; de Marcillac, P. ; Marnieros, S. ; Marrache-Kikuchi, C.A. ; Martinez, M. (Universidad de Zaragoza) ; Mazzucato, E. ; Nones, C. ; Olivieri, E. ; Ortiz de Solórzano, A. (Universidad de Zaragoza) ; Pageot, M. ; Peinaud, Y. ; Pérez, V. ; Pessina, G. ; Poda, D.V. ; Rosier, P. ; Scarpaci, J.A. ; Schmidt, B. ; Tretyak, V.I. ; Umatov, V.I. ; Zarytskyy, M.M. ; Zolotarova, A.
Cryogenic light detectors with thermal signal amplification for 0νββ search experiments
Financiación H2020 / H2020 Funds
Resumen: As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li2100MoO4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.
Idioma: Inglés
DOI: 10.1088/1748-0221/21/01/P01035
Año: 2026
Publicado en: Journal of Instrumentation 21, 01 (2026), P01035 [29 pp.]
ISSN: 1748-0221

Financiación: info:eu-repo/grantAgreement/EC/H2020/742345/EU/Cryogenic Rare-event Observatory with Surface Sensitivity/CROSS
Financiación: info:eu-repo/grantAgreement/EC/H2020/865844/EU/Bi-Isotope 0n2b Next Generation Observatory/BINGO
Tipo y forma: Article (Published version)
Área (Departamento): Área Técnica. Lab. y Talleres (Dpto. Física Teórica)
Área (Departamento): Área Física Atóm.Molec.y Nucl. (Dpto. Física Teórica)

Exportado de SIDERAL (2026-04-30-13:58:15)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
articulos > articulos-por-area > fisica_atomica,_molecular_y_nuclear



 Notice créée le 2026-04-30, modifiée le 2026-04-30


Versión publicada:
 PDF
Évaluer ce document:

Rate this document:
1
2
3
 
(Pas encore évalué)