Normal reference ranges of optical coherence tomography parameters in childhood

Elía,N. (Universidad de Zaragoza) ; Pueyo,V. (Universidad de Zaragoza) ; Altemir,I. ; Oros,D. (Universidad de Zaragoza) ; Pablo,L. E.
Normal reference ranges of optical coherence tomography parameters in childhood
Resumen: Objective To report normal reference values for peripapillary retinal nerve fibre layer (RNFL) thickness and optic disc parameters in children from a community population.

Methods The authors performed a cross-sectional study examining RNFL and optic nerve head (ONH) properties in 358 children aged between 6 and 13 years with no ocular disease. All children underwent an ophthalmic examination that included visual acuity (logMAR), stereopsis assessment (TNO) and optical coherence tomography (Cirrus OCT Zeiss, ‘Optic Disc Cube 200×200’ protocol). One eye from each subject selected at random was finally analysed. The authors evaluated the influence of height, gender and age on measurements.

Results High-quality scan data were obtained from 357 children and 344 were finally included. The mean age (SD) was 9.16 (1.7) years and the mean (SD) RNFL average thickness was 98.46 (10.79) μm. The temporal quadrant showed the thinnest RNFL (69.35±11.28 μm), followed by the nasal (71.30±13.45 μm), superior (123.65±19.49 μm) and inferior (130.18±18.13 μm) quadrants. The mean rim area (SD) and disc area (SD) were 1.59 (0.33) and 2.05 (0.39) mm2, respectively. The average cup to disc (C:D) ratio (SD) was 0.43 (0.19). The authors found no differences in any of the parameters with regard to weight, height and gender.

Conclusions This study demonstrates normative values of RNFL thickness and ONH parameters in a sample of Caucasian children from the general population.

Idioma: Inglés
DOI: 10.1136/bjophthalmol-2011-300916
Año: 2012
Publicado en: British Journal of Ophthalmology 96, 5 (2012), 665-670
ISSN: 0007-1161

Factor impacto JCR: 2.725 (2012)
Categ. JCR: OPHTHALMOLOGY rank: 9 / 59 = 0.153 (2012) - Q1 - T1
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Obstetricia y Ginecología (Dpto. Cirugía,Ginecol.Obstetr.)
Área (Departamento): Área Oftalmología (Dpto. Cirugía,Ginecol.Obstetr.)
Área (Departamento): Área Óptica (Dpto. Física Aplicada)


Derechos Reservados Derechos reservados por el editor de la revista


Exportado de SIDERAL (2026-05-15-14:55:17)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Obstetricia y Ginecología
Artículos > Artículos por área > Oftalmología
Artículos > Artículos por área > Optica



 Registro creado el 2026-05-15, última modificación el 2026-05-15


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 