Changes in frequency-doubling perimetry in patients with type i diabetes prior to retinopathy
Resumen: Purpose. To evaluate the ability of frequency-doubling technology (FDT) perimetry in detecting visual field defects in young adults with type I diabetes prior to retinopathy or with minor retinovascular changes. Methods. This comparative cross-sectional study included 30 healthy subjects and 73 age-matched patients with type I diabetes mellitus. All subjects underwent a full ocular examination including an FDT with the threshold C-20-5 strategy. Only one eye per subject was randomly included in the statistical analysis. FDT results and time to perform the test were compared between the groups. Results. The mean age was 27.1 years in the control group and 26.6 years in the diabetic group ( ). The mean period from the onset of diabetes was years, while minimal retinovascular changes were observed in 18 eyes. Mean deviation of FDT did not differ between the groups. Although global indices of FDT were within normal limits, pattern standard deviation of FDT was higher in the diabetic group ( ). The area under the receiver operating characteristic curve was 0.647 for pattern standard deviation of FDT (standard error = 0.052; ). Conclusion. FDT can detect retinal dysfunctions in diabetic patients prior to the onset of significant vascular complications.
Idioma: Inglés
DOI: 10.1155/2013/341269
Año: 2013
Publicado en: BioMed Research International 2013 (2013), 341269 [7 pp]
ISSN: 2314-6133

Factor impacto JCR: 0.0 (2013)
Categ. JCR: MEDICINE, RESEARCH & EXPERIMENTAL
Categ. JCR: BIOTECHNOLOGY & APPLIED MICROBIOLOGY

Financiación: info:eu-repo/grantAgreement/ES/DGA/B99
Financiación: info:eu-repo/grantAgreement/ES/ISCIII/FIS/PI11-01239
Financiación: info:eu-repo/grantAgreement/ES/ISCIII/PI08-0976
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Oftalmología (Departamento de Cirugía, Ginecología y Obstetricia)
Área (Departamento): Optica (Departamento de Física Aplicada)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2017-11-07-09:50:05)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Oftalmología
Artículos > Artículos por área > Optica



 Registro creado el 2016-12-16, última modificación el 2017-11-07


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)