Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects

Hernando, D. ; Roca, S. (Universidad de Zaragoza) ; Sancho, J. (Universidad de Zaragoza) ; Alesanco, Á. (Universidad de Zaragoza) ; Bailón, R. (Universidad de Zaragoza)
Validation of the apple watch for heart rate variability measurements during relax and mental stress in healthy subjects
Resumen: Heart rate variability (HRV) analysis is a noninvasive tool widely used to assess autonomic nervous system state. The market for wearable devices that measure the heart rate has grown exponentially, as well as their potential use for healthcare and wellbeing applications. Still, there is a lack of validation of these devices. In particular, this work aims to validate the Apple Watch in terms of HRV derived from the RR interval series provided by the device, both in temporal (HRM (mean heart rate), SDNN, RMSSD and pNN50) and frequency (low and high frequency powers, LF and HF) domain. For this purpose, a database of 20 healthy volunteers subjected to relax and a mild cognitive stress was used. First, RR interval series provided by Apple Watch were validated using as reference the RR interval series provided by a Polar H7 using Bland-Altman plots and reliability and agreement coefficients. Then, HRV parameters derived from both RR interval series were compared and their ability to identify autonomic nervous system (ANS) response to mild cognitive stress was studied. Apple Watch measurements presented very good reliability and agreement (>0.9). RR interval series provided by Apple Watch contain gaps due to missing RR interval values (on average, 5 gaps per recording, lasting 6.5 s per gap). Temporal HRV indices were not significantly affected by the gaps. However, they produced a significant decrease in the LF and HF power. Despite these differences, HRV indices derived from the Apple Watch RR interval series were able to reflect changes induced by a mild mental stress, showing a significant decrease of HF power as well as RMSSD in stress with respect to relax, suggesting the potential use of HRV measurements derived from Apple Watch for stress monitoring.
Idioma: Inglés
DOI: 10.3390/s18082619
Año: 2018
Publicado en: Sensors (Switzerland) 18, 8 (2018), 2619 [11 pp]
ISSN: 1424-8220

Factor impacto JCR: 3.031 (2018)
Categ. JCR: INSTRUMENTS & INSTRUMENTATION rank: 15 / 61 = 0.246 (2018) - Q1 - T1
Categ. JCR: CHEMISTRY, ANALYTICAL rank: 23 / 84 = 0.274 (2018) - Q2 - T1
Categ. JCR: ELECTROCHEMISTRY rank: 12 / 26 = 0.462 (2018) - Q2 - T2

Factor impacto SCIMAGO: 0.592 - Analytical Chemistry (Q2) - Atomic and Molecular Physics, and Optics (Q2) - Medicine (miscellaneous) (Q2) - Electrical and Electronic Engineering (Q2) - Instrumentation (Q2) - Biochemistry (Q2)

Financiación: info:eu-repo/grantAgreement/ES/DGA-FEDER/T39-17R-BSICoS
Financiación: info:eu-repo/grantAgreement/ES/DGA/T31-17R
Financiación: info:eu-repo/grantAgreement/ES/MINECO/TIN2016-76770-R
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)
Área (Departamento): Área Ingeniería Telemática (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2021-08-20-08:37:20)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2018-09-24, última modificación el 2021-08-20


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)