Twenty-Four-Hour Contact Lens Sensor Monitoring of Aqueous Humor Dynamics in Surgically or Medically Treated Glaucoma Patients
Resumen: Aim. This study assessed the 24 h circadian rhythm of intraocular pressure (IOP) using a contact lens sensor in three groups of patients with open-angle glaucoma. Methods. This study was a monocentric, cross-sectional, nonrandomized, prospective, pilot study. Eighty-nine patients were enrolled: 29 patients previously underwent an Ex-PRESS mini glaucoma device procedure (Group 1), 28 patients previously underwent Hydrus microstent implantation (Group 2), and 32 patients were currently being treated medically for primary open-angle glaucoma (Group 3). Circadian rhythm patterns were considered with five circadian indicators: fluctuation ranges, maximum, minimum, acrophase (time of peak value), and bathyphase (time of trough value). A two-tailed Mann-Whitney U-test was used to evaluate differences between groups. Results. All subjects exhibited a circadian rhythm and a nocturnal pattern. The signal fluctuation range was significantly smaller in the surgical groups than in the medically treated group (Group 1 vs. Group 3, p=0.003; Group 2 vs. Group 3, p=0.010). Subjects who underwent the Ex-PRESS procedure (Group 1) exhibited significant differences compared with the drug therapy group (Group 3) with regard to the minimum value (p=0.015), acrophase (p=0.009), and bathyphase (p=0.002). The other circadian indicators were not significantly different among groups. Conclusions. Patients who underwent IOP-lowering surgery had an intrinsic nyctohemeral rhythm. Both surgical procedures, Ex-PRESS and Hydrus, were associated with smaller signal fluctuations compared with medical treatment.
Idioma: Inglés
DOI: 10.1155/2019/9890831
Año: 2019
Publicado en: Journal of Ophthalmology 2019 (2019), 9890831 [10 pp]
ISSN: 2090-004X

Factor impacto JCR: 1.447 (2019)
Categ. JCR: OPHTHALMOLOGY rank: 41 / 60 = 0.683 (2019) - Q3 - T3
Categ. JCR: MEDICINE, RESEARCH & EXPERIMENTAL rank: 116 / 138 = 0.841 (2019) - Q4 - T3

Factor impacto SCIMAGO: 0.828 - Ophthalmology (Q2)

Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Oftalmología (Dpto. Cirugía,Ginecol.Obstetr.)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2020-07-16-09:29:12)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2019-03-13, última modificación el 2020-07-16


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)