Hypersaline infusion protocol through the portal vein may focus electroporation on tumor tissue, but is it really safe? Ppreliminary results
Resumen: Introduction: irreversible Electroporation (IRE) is highly dependent on the electrical conductivity of the tissue and the high conductivity of tumor tissue, which leads to a lower field than that in the surrounding healthy tissue. Hypersaline Infusion (HI) through the portal vein focuses IRE on scattered liver tumors, by creating a differential conductivity between the different types of tissue. The aim of this study is to determine the effects of the HI protocol on the hepatic and histological biochemical results. Methods: Ten male Sprague Dawley rats were used for HI protocol. Blood samples were collected at pre-, immediately post-, 24-hrs, 72-hrs, 1- week and 3-weeks post-HI. All the animals were sacrificed after a one-month follow-up in order to collect histological samples. Results: The mortality rate in this procedure reached 30% (3/10). Only the pH and transaminases at 24-hrs were significantly and directly linked to mortality (p=0.036 and p=0.004, respectively). The three non-surviving animals had a four-time higher AST level at 24-hrs. Natremianormalized at 24-hrs post-HI. Statistically significant differences were found in hepatic necrosis between the non-surviving (n=3) and surviving rats (n=7) (30.67 ± 10.97 vs. 2.86 ± 7.56% respectively, p=0.01). Discussion: HI through the portal system involves a significant risk of possibly lethal cytolysis and acidosis. Therefore, compensatory measures and a reduced saline overload are warranted to improve the survival rates.
Idioma: Inglés
DOI: 10.25107/2474-1647
Año: 2019
Publicado en: Clinics in Surgery 4, 1 (2019), 2335 [5 pp.]
ISSN: 2474-1647

Originalmente disponible en: Texto completo de la revista

Tipo y forma: Article (Published version)
Área (Departamento): Área Tecnología Electrónica (Dpto. Ingeniería Electrón.Com.)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes.


Exportado de SIDERAL (2023-10-23-12:20:20)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles > Artículos por área > Tecnología Electrónica



 Record created 2019-05-08, last modified 2023-10-23


Versión publicada:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)