Finger and forehead PPG signal comparison for respiratory rate estimation
Financiación H2020 / H2020 Funds
Resumen: Objective: an evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Approach: finger-PPG, forehead-PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability (PWV), pulse amplitude variability (PAV) and the respiratory- induced intensity variability (RIIV). Respiratory rate was estimated from each one of the 4 PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Main results: results show a better performance in terms of successful estimation and relative error when: i) PPG signal is recorded in the finger; ii) the respiratory rate is less than 0.4 Hz; iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. Significance: these results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that finger is better than forehead to estimate respiratory rate.
Idioma: Inglés
DOI: 10.1088/1361-6579/ab3be0
Año: 2019
Publicado en: PHYSIOLOGICAL MEASUREMENT 40 (2019), 095007 [12 pp.]
ISSN: 0967-3334

Factor impacto JCR: 2.309 (2019)
Categ. JCR: BIOPHYSICS rank: 39 / 71 = 0.549 (2019) - Q3 - T2
Categ. JCR: PHYSIOLOGY rank: 43 / 81 = 0.531 (2019) - Q3 - T2
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 49 / 87 = 0.563 (2019) - Q3 - T2

Factor impacto SCIMAGO: 0.702 - Biomedical Engineering (Q2) - Biophysics (Q2) - Physiology (Q3) - Physiology (medical) (Q3)

Financiación: info:eu-repo/grantAgreement/ES/DGA-FEDER/T39-17R-BSICoS
Financiación: info:eu-repo/grantAgreement/EC/H2020/745755/EU/Wearable Cardiorespiratory Monitor/WECARMON
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/PGC2018-095936-B-I00
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/RTI2018-097723-B-I00
Financiación: info:eu-repo/grantAgreement/ES/UZ/CUD2018-08
Tipo y forma: Article (PostPrint)
Área (Departamento): Área Ingen.Sistemas y Automát. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. You may not use the material for commercial purposes. If you remix, transform, or build upon the material, you may not distribute the modified material.


Exportado de SIDERAL (2021-08-20-08:37:35)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles



 Record created 2020-01-08, last modified 2021-08-20


Postprint:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)