Monitoring breathing rate by fusing the physiological impact of respiration on video-photoplethysmogram with head movements
Financiación H2020 / H2020 Funds
Resumen: Objective: The simple observation of breathing rate (BR) remains the first and often the most sensitive marker of acute respiratory dysfunction. In fact, there are evidences that drastic changes in BR are a predictive indicator of adverse events (i.e. cardiac arrest). The aim of this study is to develop a camera-based technology that may provide near-continuously estimation of BR considering the effect of respiration on videoPPG (vPPG). 
 Approach: The technology has been tested in two different experimental settings, including controlled BR and more challenging scenarios with spontaneous breathing pattern. Video data were processed offline to derive the vPPG signal. The method derives respiration from beat-to-beat PPG rate and morphology changes in amplitude and width driven by the physiological relationships between vPPG and respiration. Moreover, respiratory-induced head movements were used as additional source of information for the vPPG system. A combination of these methods has been exploited to estimate the respiratory rate every 10 second. 
 Main Results: According to the results, respiratory frequencies in the central range (0.2-0.4 Hz) may be estimated using vPPG system with low relative error, eR < 2 % and interquartile range of order IQR < 5 %. However, the vPPG system showed a drop in performance at respiratory range boundaries, around 0.1 Hz and 0.5 Hz.
 Significance: This camera-based technology can be used as ubiquitous BR monitoring system. However, vPPG-based systems should consider the effect of the BR in the estimation, mainly in applications where respiratory rate is out of the range 0.2-0.4 Hz.
Idioma: Inglés
DOI: 10.1088/1361-6579/ab4102
Año: 2019
Publicado en: PHYSIOLOGICAL MEASUREMENT 40 (2019), 094002 [12 pp.]
ISSN: 0967-3334

Factor impacto JCR: 2.309 (2019)
Categ. JCR: BIOPHYSICS rank: 39 / 71 = 0.549 (2019) - Q3 - T2
Categ. JCR: PHYSIOLOGY rank: 43 / 81 = 0.531 (2019) - Q3 - T2
Categ. JCR: ENGINEERING, BIOMEDICAL rank: 49 / 87 = 0.563 (2019) - Q3 - T2

Factor impacto SCIMAGO: 0.702 - Biomedical Engineering (Q2) - Biophysics (Q2) - Physiology (Q3) - Physiology (medical) (Q3)

Financiación: info:eu-repo/grantAgreement/EC/H2020/745755/EU/Wearable Cardiorespiratory Monitor/WECARMON
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/DPI2016-75458-R
Financiación: info:eu-repo/grantAgreement/ES/MINECO-FEDER/RTI2018-097723-B-I00
Tipo y forma: Artículo (PostPrint)
Área (Departamento): Área Ingen.Sistemas y Automát. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


Exportado de SIDERAL (2021-08-20-08:37:55)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2020-01-08, última modificación el 2021-08-20


Postprint:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)