Novel electronic device to quantify the cyclic fatigue resistance of endodontic reciprocating files after using and sterilization
Resumen: Background: The aim of this study was to analyze the effects of the time of use (TU) and sterilization cycles (SC) of endodontic reciprocating files on cyclic fatigue resistance. Methods: One-hundred-and-twenty (120) Procodile NiTi endodontic reciprocating instruments were selected at random and distributed into the following study groups: A: 0 sterilization cycles/0s time of use (n = 10); B: 0/60 (n = 10); C: 0/120 (n = 10); D: 1/0 (n = 10); E: 1/60 (n = 10); F: 1/120 (n = 10); G: 5/0 (n = 10); H: 5/60 (n = 10); I: 5/120 (n = 10); J: 10/0 (n = 10); K: 10/60 (n = 10); and L: 10/120 (n = 10). A dynamic cyclic fatigue device was designed using computer-aided design/computer-aided engineering (CAD/CAE) technology and created with a 3D printer to simulate the pecking motion performed by the clinician. Failure of the endodontic rotary instrument was detected by a light-emitting diode-light-dependent resistor (LED-LDR) system controlled by an Arduino driver complex and management software. The results were analyzed using the ANOVA test. Results: All pairwise comparisons presented statistically significant differences between the time to failure, number of cycles to failure and number of cycles of in-and-out movement for the time of use study groups (p < 0.001), but not in the number of sterilization cycles (p > 0.05). Conclusions: The time of use of NiTi endodontic reciprocating files negatively affects dynamic cyclic fatigue resistance. Dynamic cyclic resistance is not affected by the number of sterilization cycles.
Idioma: Inglés
DOI: 10.3390/app10144962
Año: 2020
Publicado en: APPLIED SCIENCES-BASEL 10, 14 (2020), 4962 [14 pp.]
ISSN: 2076-3417

Factor impacto JCR: 2.679 (2020)
Categ. JCR: PHYSICS, APPLIED rank: 73 / 160 = 0.456 (2020) - Q2 - T2
Categ. JCR: ENGINEERING, MULTIDISCIPLINARY rank: 38 / 91 = 0.418 (2020) - Q2 - T2
Categ. JCR: CHEMISTRY, MULTIDISCIPLINARY rank: 101 / 178 = 0.567 (2020) - Q3 - T2
Categ. JCR: MATERIALS SCIENCE, MULTIDISCIPLINARY rank: 201 / 333 = 0.604 (2020) - Q3 - T2

Factor impacto SCIMAGO: 0.435 - Computer Science Applications (Q2) - Engineering (miscellaneous) (Q2) - Process Chemistry and Technology (Q2) - Instrumentation (Q2) - Materials Science (miscellaneous) (Q2) - Fluid Flow and Transfer Processes (Q2)

Tipo y forma: Article (Published version)
Área (Departamento): Área Estomatología (Dpto. Cirugía)

Creative Commons You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.


Exportado de SIDERAL (2021-09-02-10:10:04)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Articles



 Record created 2020-09-10, last modified 2021-09-02


Versión publicada:
 PDF
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)