Photoplethysmogram Signal Morphology-Based Stress Assessment

Rinkevicius, M. ; Kontaxis, S. (Universidad de Zaragoza) ; Gil, E. (Universidad de Zaragoza) ; Bailon, R. (Universidad de Zaragoza) ; Lázaro, J. (Universidad de Zaragoza) ; Laguna, P. (Universidad de Zaragoza) ; Marozas, V.
Photoplethysmogram Signal Morphology-Based Stress Assessment
Financiación H2020 / H2020 Funds
Resumen: Stress is a healthy natural response to a perceived or actual threat. However, when stress is persistent, it may decrease work productivity, increase the risk of diseases, and affect the quality of life. Stress is reflected in physiological variables, such as heart rate, blood pressure, and pulse wave velocity among others. A photoplethys-mogram (PPG) contains information related to pulse rate and blood pressure. This study analyses parameters derived from PPG signal morphology for mental stress assessment.A low-complexity algorithm is designed using bandpass filtered higher-order derivatives of the PPG signal for estimation of six morphological parameters: the forward pulse wave amplitude A1, the systole and diastole durations T1 and Td, the time delays of reflected waves T12 and T13 from the renal and iliac sites in the central arteries, and the pulse duration Tp. The parameters were investigated on a set of 18 healthy subjects by using a modified Trier Social Stress Test.The results show that the most sensitive PPG morphology parameters to mental stress are the amplitude of forward wave A1, the duration of diastole Td, the time delay of the reflected wave T13, and the pulse-to-pulse interval Tp.
Idioma: Inglés
DOI: 10.23919/CinC49843.2019.9005748
Año: 2019
Publicado en: Computing in Cardiology 46 (2019), [4 pp]
ISSN: 2325-8861

Factor impacto SCIMAGO: 0.296 - Computer Science (miscellaneous) - Cardiology and Cardiovascular Medicine

Financiación: info:eu-repo/grantAgreement/ES/CIBER-Ibercaja-CAI/IT 16-18
Financiación: info:eu-repo/grantAgreement/ES/DGA-FEDER/T39-17R-BSICoS
Financiación: info:eu-repo/grantAgreement/ES/DGA-FSE/LMP44-18
Financiación: info:eu-repo/grantAgreement/EC/H2020/745755/EU/Wearable Cardiorespiratory Monitor/WECARMON
Financiación: info:eu-repo/grantAgreement/ES/MICIU/RTI2018-097723-B-I00
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Área Ingen.Sistemas y Automát. (Dpto. Informát.Ingenie.Sistms.)
Área (Departamento): Área Teoría Señal y Comunicac. (Dpto. Ingeniería Electrón.Com.)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


Exportado de SIDERAL (2023-09-13-10:56:09)


Visitas y descargas

Este artículo se encuentra en las siguientes colecciones:
Artículos



 Registro creado el 2021-01-22, última modificación el 2023-09-14


Versión publicada:
 PDF
Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)